The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Noncontact Tactile Display Based on Radiation Pressure of Airborne Ultrasound
Abstract
This paper describes a tactile display which provides unrestricted tactile feedback in air without any mechanical contact. It controls ultrasound and produces a stress field in a 3D space. The principle is based on a nonlinear phenomenon of ultrasound: Acoustic radiation pressure. The fabricated prototype consists of 324 airborne ultrasound transducers, and the phase and intensity of each transducer are controlled individually to generate a focal point. The DC output force at the focal point is 16 mN and the diameter of the focal point is 20 mm. The prototype produces vibrations up to 1 kHz. An interaction system including the prototype is also introduced, which enables users to see and touch virtual objects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1984) · PubMed · Cited by 908
(2020) · Questions from NeoReviews · doi:10.1542/9781610023993-2-ch27 · Cited by 480
Springer Handbook of Lasers and Optics
(2007) · Springer Handbooks · doi:10.1007/978-0-387-30420-5 · Cited by 328
Non-contact Method for Producing Tactile Sensation Using Airborne Ultrasound
Iwamoto, T., Tatezono, M., & Shinoda, H. (2008) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-69057-3_64 · Cited by 257
Self-citationTactile interfaces: a state-of-the-art survey
Benali-Khoudja, M., Hafez, M., Alexandre, J.-M., & Kheddar, A. (2004) · Cited by 168
Air jet driven force feedback in virtual reality
Suzuki, Y., & Kobayashi, M. (2005) · IEEE Computer Graphics and Applications · doi:10.1109/mcg.2005.1 · Cited by 135 · cited 1×
“Ç”
Pasquero, J., & Vincent Hayward, B. (2003) · Cited by 128
Selectively stimulating skin receptors for tactile display
Asamura, N., Yokoyama, N., & Shinoda, H. (1998) · IEEE Computer Graphics and Applications · doi:10.1109/38.734977 · Cited by 87
Self-citationNon-contact tactile sensation synthesized by ultrasound transducers
Hoshi, T., Iwamoto, T., & Shinoda, H. (2009) · IEEE World Haptics Conference (WHC) · doi:10.1109/whc.2009.4810900 · Cited by 60
Self-citationSato, K., Minamizawa, K., Kawakami, N., & Tachi, S. (2007) · ACM SIGGRAPH Emerging Technologies · doi:10.1145/1278280.1278291 · Cited by 55
Cited by
Vi, C. T., Ablart, D., Gatti, E., Velasco, C., & Obrist, M. (2017) · International Journal of Human-Computer Studies · doi:10.1016/j.ijhcs.2017.06.004 · Cited by 212
Presentation of Various Tactile Sensations Using Micro-Needle Electrotactile Display
Tezuka, M., Kitamura, N., Tanaka, K., & Miki, N. (2016) · PLOS ONE · doi:10.1371/journal.pone.0148410 · Cited by 31
Brice, D., Gibson, Z., McGuinness, F., & Rafferty, K. (2021) · Frontiers in Virtual Reality · doi:10.3389/frvir.2021.707731 · Cited by 9
Metadata
- Authors
- Hoshi, T., Takahashi, M., Iwamoto, T., & Shinoda, H.
- Venue
- IEEE Transactions on Haptics
- Published
- 2010-07
- Volume
- 3
- Issue
- 3
- Pages
- 155-165
- ISSN
- 1939-1412 (ISSN-L)
- OpenAlex
- W2103802786
- Cited by
- 470
- References
- 16
- FWCI
- 7.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noncontact Tactile Display Based on Radiation Pressure of Airborne Ultrasound. https://app.cochat.ai/papers/10.1109/toh.2010.4
- The paper
- Hoshi, T., Takahashi, M., Iwamoto, T., & Shinoda, H. (2010). Noncontact Tactile Display Based on Radiation Pressure of Airborne Ultrasound. IEEE Transactions on Haptics. https://doi.org/10.1109/toh.2010.4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.