Presentation of Various Tactile Sensations Using Micro-Needle Electrotactile Display

Open access

The DOI matches its Crossref record; 27 of the 28 references it cites were found in a registry or an index.

Abstract

Tactile displays provoke tactile sensations by artificially stimulating tactile receptors. While many types of tactile displays have been developed, electrotactile displays that exploit electric stimulation can be designed to be thin, light, flexible and thus, wearable. However, the high voltages required to stimulate tactile receptors and limited varieties of possible sensations pose problems. In our previous work, we developed an electrotactile display using a micro-needle electrode array that can drastically reduce the required voltage by penetrating through the high-impedance stratum corneum painlessly, but displaying various tactile sensations was still a challenge. In this work, we demonstrate presentation of tactile sensation of different roughness to the subjects, which is enabled by the arrangement of the electrodes; the needle electrodes are on the fingertip and the ground electrode is on the fingernail. With this arrangement, the display can stimulate the tactile receptors that are located not only in the shallow regions of the finger but also those in the deep regions. It was experimentally revealed that the required voltage was further reduced compared to previous devices and that the roughness presented by the display was controlled by the pulse frequency and the switching time, or the stimulation flow rate. The proposed electrotactile display is readily applicable as a new wearable haptic device for advanced information communication technology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0148410

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig 1 Conceptual images of the electrotactile displays. (a) Electrotactile display consisting of micro-needle electrodes [20]. The source electrode is located in the center of the electrode array, and the stimulating current only passes through the shallow region of the finger skin. (b) Newly proposed “Two-Side Needle-Flat device” with the ground electrode on the fingernail. The stimulating current passes through the finger and stimulates all the tactile receptors distributed in the skin.
Fig 1 Conceptual images of the electrotactile displays. (a) Electrotactile display consisting of micro-needle electrodes [20]. The source electrode is located in the center of the electrode array, and the stimulating current only passes through the shallow region of the finger skin. (b) Newly proposed “Two-Side Needle-Flat device” with the ground electrode on the fingernail. The stimulating current passes through the finger and stimulates all the tactile receptors distributed in the skin.CC BY · PubMed Central
Fig 2 Process for fabricating the wire array. a) PMMA wire holder was mechanically fabricated. b) Titanium wires were bent and positioned into the holes of the holder, then fixed with PDMS. c) The needle shape was formed by electrochemical etching. d) Photo of the fabricated device.
Fig 2 Process for fabricating the wire array. a) PMMA wire holder was mechanically fabricated. b) Titanium wires were bent and positioned into the holes of the holder, then fixed with PDMS. c) The needle shape was formed by electrochemical etching. d) Photo of the fabricated device.CC BY · PubMed Central
Fig 3 Photo of tactile display and schematic image of the experimental system.
Fig 3 Photo of tactile display and schematic image of the experimental system.CC BY · PubMed Central
Fig 4 The Two-Side Needle-Flat device and schematic image of the perception test. (a) Photos of the tactile display and the needle array. (b) Illustration of the stimulation flow.
Fig 4 The Two-Side Needle-Flat device and schematic image of the perception test. (a) Photos of the tactile display and the needle array. (b) Illustration of the stimulation flow.CC BY · PubMed Central
Fig 5 The threshold voltage of the flat-electrode device, the One-Side Needle device, and the newly proposed Two-Side Needle-Flat device with respect to the pulse frequency. The results shown are for 17 subjects. The error bars represent standard deviations.
Fig 5 The threshold voltage of the flat-electrode device, the One-Side Needle device, and the newly proposed Two-Side Needle-Flat device with respect to the pulse frequency. The results shown are for 17 subjects. The error bars represent standard deviations.CC BY · PubMed Central
Fig 6 Results for three subjects. a) Statistically significant results for one subject, p < .05. b) The threshold voltage of the Two-Side Needle-Flat device is bigger than that of the One-Side Needle device, and the difference in threshold between the flat-electrode device and the Two-Side Needle-Flat device is not statistically significant. c) No significant difference in threshold between the Two-Side Needle-Flat device and the One-Side Needle device.
Fig 6 Results for three subjects. a) Statistically significant results for one subject, p < .05. b) The threshold voltage of the Two-Side Needle-Flat device is bigger than that of the One-Side Needle device, and the difference in threshold between the flat-electrode device and the Two-Side Needle-Flat device is not statistically significant. c) No significant difference in threshold between the Two-Side Needle-Flat device and the One-Side Needle device.CC BY · PubMed Central
Fig 7 The difference between the threshold voltage and the painful voltage for the One-Side Needle and Two-Side Needle-Flat devices with respect to the frequency. The error bars represent standard deviations. The results shown are for 17 subjects. The range did not change with the frequency, but the Two-Side Needle-Flat device had a wider range.
Fig 7 The difference between the threshold voltage and the painful voltage for the One-Side Needle and Two-Side Needle-Flat devices with respect to the frequency. The error bars represent standard deviations. The results shown are for 17 subjects. The range did not change with the frequency, but the Two-Side Needle-Flat device had a wider range.CC BY · PubMed Central
Fig 8 Relationship between the comfortable voltage, threshold voltage and painful voltage of the Two-Side Needle-Flat device. Data are averages for 17 subjects.
Fig 8 Relationship between the comfortable voltage, threshold voltage and painful voltage of the Two-Side Needle-Flat device. Data are averages for 17 subjects.CC BY · PubMed Central
Fig 9 Results of the perception test. a) The grayscale blocks correspond to the averages of the roughness reported by 11 subjects. b) The averages of the roughness judgements (averaged across frequencies) for 11 subjects. The error bars represent the standard deviations.
Fig 9 Results of the perception test. a) The grayscale blocks correspond to the averages of the roughness reported by 11 subjects. b) The averages of the roughness judgements (averaged across frequencies) for 11 subjects. The error bars represent the standard deviations.CC BY · PubMed Central
Fig 10 Questionnaire results. The questionnaire items and the average of the answers of 11 subjects with the standard deviations.
Fig 10 Questionnaire results. The questionnaire items and the average of the answers of 11 subjects with the standard deviations.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 27 references

Research works printed but not linked: 3

  1. H Kajimoto, 2003, Proc. of 11th Symposium on Haptic Interfaces for Virtual Environment. and Teleoperator Systems
  2. H Kajimoto, 1999, Proc. of The 9th Int. Conf. on Artificial Reality and Telexistence, 107
  3. H Kajimoto, 2003, Proc. of 13th International Symposium on Measurement and Control in Robotics (ISMCR), 83

Cited by

See all 33

Metadata

Authors
Tezuka, M., Kitamura, N., Tanaka, K., & Miki, N.
Affiliations
Keio University (JP)
Corresponding author
  • Tezuka, Mayuko
  • Miki, Norihisa
Venue
PLOS ONE
Published
2016-02-04
Volume
11
Issue
2
Pages
e0148410
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2255111570
Cited by
31
References
28
Citations by year
2026: 2 · 2025: 3 · 2024: 5 · 2022: 1 · 2021: 4 · 2020: 3 · 2019: 4 · 2018: 2 · 2017: 5 · 2016: 2
FWCI
2.76
Type
journal article
Language
en
Open access
Locations
  • PLoS ONE (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • Japan Science and Technology Agency
  • Precursory Research for Embryonic Science and Technology
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
Keywords
tactile perception, roughness perception, wearable haptic device, stratum corneum, pulse frequency, switching time, fingertip stimulation, tactile receptors
MeSH terms
Electric Stimulation, Equipment Design, Humans, Needles, Touch, Threshold Limit Values, Touch Perception

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Presentation of Various Tactile Sensations Using Micro-Needle Electrotactile Display. https://app.cochat.ai/papers/10.1371/journal.pone.0148410
The paper
Tezuka, M., Kitamura, N., Tanaka, K., & Miki, N. (2016). Presentation of Various Tactile Sensations Using Micro-Needle Electrotactile Display. PLOS ONE. https://doi.org/10.1371/journal.pone.0148410

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.