Effect of Waveform on Tactile Perception by Electrovibration Displayed on Touch Screens
Open accessThe DOI matches its Crossref record; 54 of the 55 references it cites were found in a registry or an index.
Abstract
In this study, we investigated the effect of input voltage waveform on our haptic perception of electrovibration on touch screens. Through psychophysical experiments performed with eight subjects, we first measured the detection thresholds of electrovibration stimuli generated by sinusoidal and square voltages at various fundamental frequencies. We observed that the subjects were more sensitive to stimuli generated by square wave voltage than sinusoidal one for frequencies lower than 60 Hz. Using Matlab simulations, we showed that the sensation difference of waveforms in low fundamental frequencies occurred due to the frequency-dependent electrical properties of human skin and human tactile sensitivity. To validate our simulations, we conducted a second experiment with another group of eight subjects. We first actuated the touch screen at the threshold voltages estimated in the first experiment and then measured the contact force and acceleration acting on the index fingers of the subjects moving on the screen with a constant speed. We analyzed the collected data in the frequency domain using the human vibrotactile sensitivity curve. The results suggested that Pacinian channel was the primary psychophysical channel in the detection of the electrovibration stimuli caused by all the square-wave inputs tested in this study. We also observed that the measured force and acceleration data were affected by finger speed in a complex manner suggesting that it may also affect our haptic perception accordingly.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“there is significant literature on tactile thresholds for physical stimuli [20,36], the effect of aging on tactile ability [66], and the tactile “science” supporting Braille reading and pattern recognition [76]”
From Design Guidelines and Recommendations for Multimodal, Touchscreen-based Graphics (2020) · cites this paper as [76]
Citations
Cites
Transformed Up-Down Methods in Psychoacoustics
Levitt, H. (1971) · The Journal of the Acoustical Society of America · doi:10.1121/1.1912375 · Cited by 5,477
Four channels mediate the mechanical aspects of touch
Bolanowski, S. J., Gescheider, G. A., Verrillo, R. T., & Checkosky, C. M. (1988) · The Journal of the Acoustical Society of America · doi:10.1121/1.397184 · Cited by 937 · cited 5×
“els [18], [21].”
BackgroundResultInfluentialElectrotactile and vibrotactile displays for sensory substitution systems
Kaczmarek, K. A., Webster, J. G., Bach-y-Rita, P., & Tompkins, W. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68204 · Cited by 827 · cited 1×
“Previous studies showed that the human skin (especially sweat ducts and the stratumcorneum) is not a perfect dielectric and has frequency-dependent resistive properties [13], [16], [27], [28].”
BackgroundAdaptive procedures in psychophysical research
Leek, M. R. (2001) · Perception & Psychophysics · doi:10.3758/bf03194543 · Cited by 808 · cited 1×
“cedure decreases the duration of the experimentation by reducing the number of trials [22], [30], [31], [34], [35].”
BackgroundTeslaTouch: electrovibration for touch surfaces
Bau, O., Poupyrev, I., Israr, A., & Harrison, C. (2010) · Proceedings of the 23nd annual ACM symposium on User interface software and technology · doi:10.1145/1866029.1866074 · Cited by 664 · cited 9×
“human tactile perception of electrovibration have already been investigated using pure sine waves [1], there is no earlier study on how our perception changes when another waveform is used.”
BackgroundMethodInfluentialDerler, S., & Gerhardt, L.-C. (2012) · Tribology Letters · doi:10.1007/s11249-011-9854-y · Cited by 425 · cited 2×
“difference might be caused by the experimental factors such as the angle of contact, movement direction, environmental factors such as finger moisture and contact temperature, the number of subjects, and subject-to-subject variability such as the variability in fingerprints and finger electromechanical properties [39]…”
BackgroundFinger pad friction and its role in grip and touch
Adams, M. J., Johnson, S. A., Lefèvre, P., Lévesque, V., Hayward, V., André, T., & Thonnard, J.-L. (2013) · Journal of The Royal Society Interface · doi:10.1098/rsif.2012.0467 · Cited by 293 · cited 4×
“[38], [39].”
BackgroundMethodInfluentialBensmaÏa, S. J., & Hollins, M. (2003) · Somatosensory & Motor Research · doi:10.1080/0899022031000083825 · Cited by 280 · cited 1×
“The earlier studies in tribology literature support this result [44], [49], [50], [51], [52].”
ResultFriction of human skin against smooth and rough glass as a function of the contact pressure
Derler, S., Gerhardt, L.-C., Lenz, A., Bertaux, E., & Hadad, M. (2009) · Tribology International · doi:10.1016/j.triboint.2008.11.009 · Cited by 208 · cited 2×
“difference might be caused by the experimental factors such as the angle of contact, movement direction, environmental factors such as finger moisture and contact temperature, the number of subjects, and subject-to-subject variability such as the variability in fingerprints and finger electromechanical properties [39]…”
BackgroundGescheider, G. A., Bolanowski, S. J., Pope, J. V., & Verrillo, R. T. (2002) · Somatosensory & Motor Research · doi:10.1080/08990220220131505 · Cited by 203 · cited 9×
“els [18], [21].”
BackgroundMethodResultInfluential
Research works printed but not linked: 2
- linjama, 2009, E-sense screen: Novel haptic display with capacitive electrosensory interface, Proc 4th Workshop Haptic Audio Interaction Des
- 10.1016/j.triboint.2014.02.018 · DOI
Cited by
Items 101–127 of 127
Tomita, H., Saga, S., Takahashi, S. I., & Kajimoto, H. (2020) · Lecture notes in computer science · doi:10.1007/978-3-030-58147-3_39 · Cited by 1
“Vardar et al. investigated how displayed waveforms affect haptic perceptions of vibration under electrostatic tactile display [8].”
BackgroundRoughness Perception of Virtual Gratings by Electrovibration
Vardar, Y. (2020) · Springer series on touch and haptic systems · doi:10.1007/978-3-030-52252-0_6 · Cited by 1
Self-citationALPDOĞAN, N. L., & Ayyıldız, M. (2021) · European Journal of Science and Technology · doi:10.31590/ejosat.1014803 · Cited by 1
Effect of Subthreshold Vibration on the Perception of Electrovibration
Balasubramanian, J. K., Ray, R. K., & Manivannan, M. (2022) · Lecture notes in computer science · doi:10.1007/978-3-031-15019-7_4 · Cited by 1
Improvement of a haptic feedback using Pb(Zr,Ti)O3 thin films on German silver foils
Bach, P., Kweon, S., Hida, H., & Kanno, I. (2023) · Microsystem Technologies · doi:10.1007/s00542-023-05486-x · Cited by 1
“If the frequency goes beyond 1 kHz, on the contrary, the detection thresholds dramatically increase, making the skin perception quite difficult (Vardar et al. 2017).”
BackgroundRecognition of 2D Shapes with Varying Complexity and Thickness on an Ultrasonic Tactile Display
Rohou--Claquin, B., Kaci, A., Lemaire‐Semail, B., & Gueorguiev, D. (2024) · Lecture notes in computer science · doi:10.1007/978-3-031-70061-3_5 · Cited by 3
“Studies have investigated the perception of important parameters of the simulated frictional cues such as a signal’s intensity [11] and contrast [5, 19], its waveform [29], the stimulus angle [8], and the influence of scanning speed [12].”
Waveform-dependent mechanical signatures shape human vibrotactile perceptionPreprint
Bonnet, S., Watkins, R. H., Ericsson, R., Daumas, H., & Ackerley, R. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.11.10.687548 · Cited by 1
“This aligns well with prior findings [18], [19], [20] and can be attributed to two complementary mechanisms.”
Kenanoglu, C. U., & Vardar, Y. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.08.05.743019 · Cited by 1
“Under actuation, both the measured real contact area and the tangential force oscillated at twice the drive frequency, consistent with the quadratic dependence of electrostatic attraction on voltage [15, 24, 27, 34, 35] (Supplementary Text, Fig.”
Self-citationConclusion and Future Directions
Vardar, Y. (2020) · Springer series on touch and haptic systems · doi:10.1007/978-3-030-52252-0_7
Self-citationEffect of Masking on Tactile Perception by Electrovibration
Vardar, Y. (2020) · Springer series on touch and haptic systems · doi:10.1007/978-3-030-52252-0_4
Self-citationTexture Rendering by Electrovibration
Vardar, Y. (2020) · Springer series on touch and haptic systems · doi:10.1007/978-3-030-52252-0_5
Self-citationVardar, Y. (2020) · Springer series on touch and haptic systems · doi:10.1007/978-3-030-52252-0_2
Self-citationVardar, Y. (2020) · Springer series on touch and haptic systems · doi:10.1007/978-3-030-52252-0_1
Self-citationSun, Z., Zhang, M., & Sun, X. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3497059 · Cited by 1
“Perception experiments usually involve about ten participants [4], [7], [13], [24], [25], so we also selected 12 participants.”
InfluentialEffects of Distributed Friction During Sliding Touch
Harnett, M., Kumar, P. R., & Friesen, R. F. (2025) · IEEE Transactions on Haptics · doi:10.1109/toh.2025.3581009 · Cited by 1
“Manyrecentfriction-modulatedscreensexploit anelectroadhesiveeffecttoincreasefrictionforcesonabarefingeras afunctionofappliedvoltage[1],[2],[3].”
Efficiency-Aware Two-Stage Hybrid Processing Method for Tactile Data Outliers
Shi, X., Zhang, J., Hua, W., & Han, S. (2025) · International Conference on Communications, Circuits and Systems · doi:10.1109/icccas65806.2025.11102520
“In addition, during the signal collection process, there are multiple causes for the emergence of outliers in tactile data, such as unstable performance of measurement equipment, sudden changes in collection speed and pressing force, human operation errors, etc. [9], [10].”
Fei, H., Zhang, Y., & Sun, X. (2025) · ACM Symposium on User Interface Software and Technology (UIST) · doi:10.1145/3746059.3747599
“For instance, studies by Vardar et al. [14] and Ozdamar et al. [15] demonstrated that sliding speed significantly influences tactile perception induced by electrovibration.”
Sabino, T. S., Carneiro, A. M. C., Carvalho, R. P., & Pires, F. M. A. (2026) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2025.118688
Monitoring Electrostatic Adhesion Forces via Acoustic Pressure
Huacen, W., Zou, J., Zheng, Z., Shi, Z., & Wang, H. (2026) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2026.3662557
“E LECTROSTATIC adhesion (EA) is a lightweight [1], low energy consumption [2], and highly adaptable [3] adhesion technique used in crawling and climbing robotics [4], [5], [6], [7], haptic devices [8], [9], [10], and robotic handling end effectors [11], [12], [13].”
Ryuga, S. A. N. O., NOMURA, H., Abe, T., & Sohgawa, M. (2026) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/ae5b86
Huloux, N. (2021) · theses.fr (ABES) · doi:10.70675/6f35c209z4a56z4de1za1d4zc5ba0e026334 · Cited by 3
Jamalzadeh, M., Rekik, Y., Rupin, M., & Giraud, F. (2026) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3772318.3791004
“This vibration frequency has the lowest detection threshold for square waves on haptic surfaces [50].”
Karimi, M., Briem, K., Kristjansson, A. K., Brynjólfsson, S., & Unnþórsson, R. (2026) · Sensors · doi:10.3390/s26092664
“Vardar et al. [29] reported that although square waves can be perceived as significantly stronger than sinusoidal signals, particularly at frequencies lower than 60 Hz, the benefit diminishes at higher frequencies where perceptual sensitivity to waveform shape converges.”
Mou, Z.-H., Yao, B.-G., Zhang, Y.-F., & Zhang, F. (2026) · AIP Advances · doi:10.1063/5.0325376
Miura, T., Yabu, K.-I., Katagiri, A., Matsuo, M., Okochi, N., Yasu, K., Sakajiri, M., & Ifukube, T. (2026) · Journal of Sensor and Actuator Networks · doi:10.3390/jsan15040069
“Electrotactile and electrovibration approaches [35,58,69] avoid mechanical pins entirely but couple strongly to skin moisture and contact area, making calibration difficult.”
Electroadhesion in Polymer–Polymer Systems: From Theory and Modeling to Emerging Applications
Sharov, K. I., Popyrina, T. N., Nikulova, U. V., & Shapagin, A. V. (2026) · Polymers · doi:10.3390/polym18182263
“Electrovibration [87,88]—using alternating current voltage with different amplitudes, frequencies, and waveforms; • Electroadhesion [89,90]—using direct current voltage.”
Metadata
- Authors
- Vardar, Y., Guclu, B., & Basdogan, C.
- Affiliations
- Koç University (TR)
- Venue
- IEEE Transactions on Haptics
- Published
- 2017-10-01
- Volume
- 10
- Issue
- 4
- Pages
- 488-499
- ISSN
- 1939-1412 (ISSN-L)
- 2329-4051
- 2334-0134
- OpenAlex
- W2616714939
- Cited by
- 130
- References
- 55
- Citations by year
- 2026: 13 · 2025: 11 · 2024: 13 · 2023: 6 · 2022: 10 · 2021: 13 · 2020: 22 · 2019: 25 · 2018: 15 · 2017: 2
- FWCI
- 10.06
- Type
- journal article
- Language
- en
- Open access
- green
- hal.science
- Locations
- IEEE Transactions on Haptics (publishedVersion)
- PubMed (publishedVersion)
- HAL (submittedVersion, other-oa)
- Funders
- The Scientific and Technological Research Council of Turkey (TUBITAK)
- Student Fellowship Program (BIDEB-2211)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
- Physical Sciences › Computer Science › Human-Computer Interaction › Interactive and Immersive Displays
- Keywords
- electrovibration, haptic feedback, touch screen, voltage waveform, square wave, sinusoidal voltage, detection threshold, vibrotactile sensitivity, skin electrical properties, finger force, fundamental frequency
- MeSH terms
- Adult, Computers, Electric Stimulation, Female, Fingers, Humans, Male, Psychophysics, Vibration, Friction, Signal Detection, Psychological, Touch Perception, Accelerometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.