The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Ordinal Measures for Iris Recognition
Abstract
Images of a human iris contain rich texture information useful for identity authentication. A key and still open issue in iris recognition is how best to represent such textural information using a compact set of features (iris features). In this paper, we propose using ordinal measures for iris feature representation with the objective of characterizing qualitative relationships between iris regions rather than precise measurements of iris image structures. Such a representation may lose some image-specific information, but it achieves a good trade-off between distinctiveness and robustness. We show that ordinal measures are intrinsic features of iris patterns and largely invariant to illumination changes. Moreover, compactness and low computational complexity of ordinal measures enable highly efficient iris recognition. Ordinal measures are a general concept useful for image analysis and many variants can be derived for ordinal feature extraction. In this paper, we develop multilobe differential filters to compute ordinal measures with flexible intralobe and interlobe parameters such as location, scale, orientation, and distance. Experimental results on three public iris image databases demonstrate the effectiveness of the proposed ordinal feature models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kendall, M. G. (1957) · Biometrika · doi:10.2307/2333282 · Cited by 6,383
On the Theory of Scales of Measurement
Stevens, S. S. (1946) · Science · doi:10.1126/science.103.2684.677 · Cited by 4,761 · cited 2×
“Stevens suggested four levels of measurements from coarse to fine: nominal, ordinal, interval, and ratio measures [21].”
BackgroundHigh confidence visual recognition of persons by a test of statistical independence
Daugman, J. G. (1993) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.244676 · Cited by 3,252
Moran, P. A. P., & Kendall, M. G. (1951) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2980903 · Cited by 2,573
Macmillan, N. A., & Creelman, C. D. (2004) · doi:10.4324/9781410611147 · Cited by 1,269
A human identification technique using images of the iris and wavelet transform
Boles, W. W., & Boashash, B. (1998) · IEEE Transactions on Signal Processing · doi:10.1109/78.668573 · Cited by 1,130
Personal identification based on iris texture analysis
Ma, L., Tan, T., Wang, Y., & Zhang, D. (2003) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2003.1251145 · Cited by 960
Self-citationEfficient Iris Recognition by Characterizing Key Local Variations
Ma, L., Tan, T., Wang, Y., & Zhang, D. (2004) · IEEE Transactions on Image Processing · doi:10.1109/tip.2004.827237 · Cited by 931
Self-citationRate Coding Versus Temporal Order Coding: What the Retinal Ganglion Cells Tell the Visual Cortex
Rullen, R. V., & Thorpe, S. J. (2001) · Neural Computation · doi:10.1162/08997660152002852 · Cited by 487
Person Identification Technique Using Human Iris Recognition
Tisse, C.-L., Martin, L., Torres, L., & Robert, M. (2002) · HAL · Cited by 457
Monro, D. M., Rakshit, S., & Zhang, D. (2007) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2007.1002 · Cited by 452
DeAngelis, G. C., Ohzawa, I., & Freeman, R. D. (1993) · Journal of Neurophysiology · doi:10.1152/jn.1993.69.4.1091 · Cited by 427
Statistical Richness of Visual Phase Information: Update on Recognizing Persons by Iris Patterns
Daugman, J. (2001) · International Journal of Computer Vision · doi:10.1023/a:1012365806338 · Cited by 422
A machine-vision system for iris recognition
Wildes, R. P., Asmuth, J. C., Green, G. L., Hsu, S. C., Kolczynski, R. J., Matey, J. R., & McBride, S. E. (1996) · Machine Vision and Applications · doi:10.1007/bf01246633 · Cited by 405
Ordinal measures for image correspondence
Bhat, D. N., & Nayar, S. K. (1998) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.677275 · Cited by 353
A Bayesian Approach to Deformed Pattern Matching of Iris Images
Thornton, J. R., Savvides, M., & Kumar, B. V. K. V. (2007) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2007.1006 · Cited by 151
Configuration based scene classification and image indexing
Lipson, P., Grimson, W. E. L., & Sinha, P. (2002) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · doi:10.1109/cvpr.1997.609453 · Cited by 134
Ávila, C. S., & Sánchez-Reillo, R. (2004) · Pattern Recognition · doi:10.1016/j.patcog.2004.07.004 · Cited by 131
The Gaussian Derivative model for spatial-temporal vision: I. Cortical model
Young, R. A., Lesperance, R. M., & Meyer, W. W. (2001) · Spatial Vision · doi:10.1163/156856801753253582 · Cited by 127
Qualitative Representations for Recognition
Sinha, P. (2002) · Lecture notes in computer science · doi:10.1007/3-540-36181-2_25 · Cited by 94
Robust Encoding of Local Ordinal Measures: A General Framework of Iris Recognition
Sun, Z., Tan, T., & Wang, Y. (2004) · Lecture notes in computer science · doi:10.1007/978-3-540-25976-3_25 · Cited by 73
Self-citationPerceiving and recognizing three-dimensional forms
Sinha, P. (1996) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 32
Dissociated Dipoles: Image Representation via Non-local Comparisons
Balas, B., & Sinha, P. (2003) · Defense Technical Information Center (DTIC) · doi:10.21236/ada459820 · Cited by 28
Receptive Field Structures for Recognition
Balas, B., & Sinha, P. (2006) · Neural Computation · doi:10.1162/089976606775623315 · Cited by 13
Cited by
A Light CNN for Deep Face Representation With Noisy Labels
Wu, X., He, R., Sun, Z., & Tan, T. (2018) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2018.2833032 · Cited by 1,186
Self-citationGalbally, J., Marcel, S., & Fierrez, J. (2014) · IEEE Transactions on Image Processing · doi:10.1109/tip.2013.2292332 · Cited by 613
A review of biometric technology along with trends and prospects
Unar, J. A., Seng, W. C., & Abbasi, A. (2014) · Pattern Recognition · doi:10.1016/j.patcog.2014.01.016 · Cited by 404
Iris Recognition With Off-the-Shelf CNN Features: A Deep Learning Perspective
Nguyen, K., Fookes, C., Ross, A., & Sridharan, S. (2018) · IEEE Access · doi:10.1109/access.2017.2784352 · Cited by 355
Efficient and robust segmentation of noisy iris images for non-cooperative iris recognition
Tan, T., He, Z., & Sun, Z. (2010) · Image and Vision Computing · doi:10.1016/j.imavis.2009.05.008 · Cited by 271
Self-citation
Metadata
- Authors
- Sun, Z., & Tan, T.
- Venue
- IEEE Transactions on Pattern Analysis and Machine Intelligence
- Published
- 2009-12
- Volume
- 31
- Issue
- 12
- Pages
- 2211-2226
- ISSN
- 0162-8828 (ISSN-L)
- OpenAlex
- W2149999708
- Cited by
- 295
- References
- 24
- FWCI
- 22.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.