The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Active Polarization Descattering
Abstract
Vision in scattering media is important but challenging. Images suffer from poor visibility due to backscattering and attenuation. Most prior methods for scene recovery use active illumination scanners (structured and gated), which can be slow and cumbersome, while natural illumination is inapplicable to dark environments. The current paper addresses the need for a non-scanning recovery method, that uses active scene irradiance. We study the formation of images under widefield artificial illumination. Based on the formation model, the paper presents an approach for recovering the object signal. It also yields rough information about the 3D scene structure. The approach can work with compact, simple hardware, having active widefield, polychromatic polarized illumination. The camera is fitted with a polarization analyzer. Two frames of the scene are taken, with different states of the analyzer or polarizer. A recovery algorithm follows the acquisition. It allows both the backscatter and the object reflection to be partially polarized. It thus unifies and generalizes prior polarization-based methods, which had assumed exclusive polarization of either of these components. The approach is limited to an effective range, due to image noise and illumination falloff. Thus, the limits and noise sensitivity are analyzed. We demonstrate the approach in underwater field experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Imaging skin pathology with polarized light
Jacques, S. L., Ramella-Roman, J. C., & Lee, K. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1484498 · Cited by 582
Cited by
An Underwater Image Enhancement Benchmark Dataset and Beyond
Li, C., Guo, C., Ren, W., Cong, R., Hou, J., Kwong, S., & Tao, D. (2020) · IEEE Transactions on Image Processing · doi:10.1109/tip.2019.2955241 · Cited by 2,373
Human-Visual-System-Inspired Underwater Image Quality Measures
Panetta, K., Gao, C., & Agaian, S. (2016) · IEEE Journal of Oceanic Engineering · doi:10.1109/joe.2015.2469915 · Cited by 1,718
Color balance and fusion for underwater image enhancement
Ancuti, C. O., Ancuti, C., De Vleeschouwer, C., & Bekaert, P. (2018) · IEEE Transactions on Image Processing · doi:10.1109/tip.2017.2759252 · Cited by 1,357
Underwater Image Enhancement via Minimal Color Loss and Locally Adaptive Contrast Enhancement
Zhang, W., Zhuang, P., Sun, H.-H., Li, G., Kwong, S., & Li, C. (2022) · IEEE Transactions on Image Processing · doi:10.1109/tip.2022.3177129 · Cited by 888
Real-World Underwater Enhancement: Challenges, Benchmarks, and Solutions Under Natural Light
Liu, R., Fan, X., Zhu, M., Hou, M., & Luo, Z. (2020) · IEEE Transactions on Circuits and Systems for Video Technology · doi:10.1109/tcsvt.2019.2963772 · Cited by 863
Metadata
- Authors
- Treibitz, T., & Schechner, Y. Y.
- Venue
- IEEE Transactions on Pattern Analysis and Machine Intelligence
- Published
- 2009-03
- Volume
- 31
- Issue
- 3
- Pages
- 385-399
- ISSN
- 0162-8828 (ISSN-L)
- OpenAlex
- W2155586404
- Cited by
- 514
- References
- 1
- FWCI
- 6.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.