The DOI matches its Crossref record.
Optimum Megawatt-Frequency Control of Multiarea Electric Energy Systems
Abstract
The North American Power Systems Interconnection Committee recommends that each control area set its frequency bias equal to the so-called area frequency response characteristic (AFRC). The authors question seriously the basis for this practice and prove by the methods of optimum control that better response and wider stability margins can be obtained by lower bias settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Megawatt-Frequency Control Problem: A New Approach Via Optimal Control Theory
Fosha, C., & Elgerd, O. (1970) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1970.292603 · Cited by 693
Self-citationRenewable energy sources and frequency regulation: survey and new perspectives
Bevrani, H., Ghosh, A., & Ledwich, G. (2010) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2009.0049 · Cited by 574
Pandey, S. K., Mohanty, S. R., & Kishor, N. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.04.029 · Cited by 561
Simulation and optimization in an AGC system after deregulation
Donde, V., Pai, M. A., & Hiskens, I. A. (2001) · IEEE Transactions on Power Systems · doi:10.1109/59.932285 · Cited by 516
Nanda, J., Mishra, S., & Saikia, L. C. (2009) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2016588 · Cited by 411
Adaptive fuzzy gain scheduling for load frequency control
Talaq, J., & Al-Basri, F. (1999) · IEEE Transactions on Power Systems · doi:10.1109/59.744505 · Cited by 370
Load frequency control of a realistic power system with multi-source power generation
Parmar, K. P. S., Majhi, S., & Kothari, D. P. (2012) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2012.04.040 · Cited by 364
Alhelou, H. H., Hamedani-Golshan, M.-E., Zamani, R., Heydarian-Forushani, E., & Siano, P. (2018) · Energies · doi:10.3390/en11102497 · Cited by 349
“A feedback and loop gain is used in [153] to offset the disturbances.”
MethodRaju, M., Saikia, L. C., & Sinha, N. (2016) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2016.01.037 · Cited by 282
Sahu, B. K., Pati, S., Mohanty, P. K., & Panda, S. (2015) · Applied Soft Computing · doi:10.1016/j.asoc.2014.11.027 · Cited by 261
Kalyan, C., Goud, B., Reddy, C., Ramadan, H., Bajaj, M., & Ali, Z. (2021) · Energies · doi:10.3390/en14175387 · Cited by 61
Metadata
- Authors
- Elgerd, O., & Fosha, C.
- Venue
- IEEE Transactions on Power Apparatus and Systems
- Published
- 1970-04
- Volume
- PAS-89
- Issue
- 4
- Pages
- 556-563
- ISSN
- 0018-9510 (ISSN-L)
- OpenAlex
- W2169799656
- Cited by
- 810
- References
- 0
- FWCI
- 7.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.