CoChat

Water Cycle Algorithm Optimized Type II Fuzzy Controller for Load Frequency Control of a Multi-Area, Multi-Fuel System with Communication Time Delays

Open access

The DOI matches its Crossref record; 27 of the 28 references it cites were found in a registry or an index.

Abstract

This paper puts forward the implementation of an intelligent type II fuzzy PID (T2-FPID) controller tweaked with a water cycle algorithm (WCA), subjected to an error multiplied with time area over integral (ITAE) objective index for regularizing the variations in frequency and interline power flow of an interconnected power system during load disturbances. The WCA-based T2-FPID is tested on a multi-area (MA) system comprising thermal-hydro-nuclear (THN) (MATHN) plants in each area. The dynamical behavior of the system is analyzed upon penetrating area 1 with a step load perturbation (SLP) of 10%. However, power system practicality constraints, such as generation rate constraints (GRCs) and time delays in communication (CTDs), are examined. Afterward, a territorial control scheme of a superconducting magnetic energy storage system (SMES) and a unified power flow controller (UPFC) is installed to further enhance the system performance. The dominancy of the presented WCA-tuned T2-FPID is revealed by testing it on a widely used dual-area hydro-thermal (DAHT) power system model named test system 1 in this paper. Analysis reveals the efficacy of the presented controller with other approaches reported in the recent literature. Finally, secondary and territorial regulation schemes are subjected to sensitivity analysis to deliberate the robustness.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/en14175387

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Dual-area conventional hydro-thermal plant (DAHT) (test system 1) [24]. Figure 1. Dual-area conventional hydro-thermal plant (DAHT) (test system 1) [24].
Figure 1 Dual-area conventional hydro-thermal plant (DAHT) (test system 1) [24]. Figure 1. Dual-area conventional hydro-thermal plant (DAHT) (test system 1) [24].CC-BY · From the PDF
Image 2
CC-BY · From the PDF
Figure 3 MFs implemented for the FLC. Figure 3. MFs implemented for the FLC.
Figure 3 MFs implemented for the FLC. Figure 3. MFs implemented for the FLC.CC-BY · From the PDF
Figure 4 Structure of the T2-FPID controller. Figure 4. Structure of the T2-FPID controller.
Figure 4 Structure of the T2-FPID controller. Figure 4. Structure of the T2-FPID controller.CC-BY · From the PDF
Figure 5 UPFC damping controller [21]. Figure 5. UPFC damping controller [21].
Figure 5 UPFC damping controller [21]. Figure 5. UPFC damping controller [21].CC-BY · From the PDF
Image 6
CC-BY · From the PDF
Figure 7 Cont .
Figure 7 Cont .CC-BY · From the PDF
Image 8
CC-BY · From the PDF
Figure 8 Responses for case 2: ( a ) Δ f 1 ( b ) Δ P tie12 and ( c ) Figure 8. Responses for case 2: ( a ) D f 1 ( b ) D Ptie 12 and ( c ) D f 2 .
Figure 8 Responses for case 2: ( a ) Δ f 1 ( b ) Δ P tie12 and ( c ) Figure 8. Responses for case 2: ( a ) D f 1 ( b ) D Ptie 12 and ( c ) D f 2 .CC-BY · From the PDF
Image 10
CC-BY · From the PDF
Figure 10 Responses for case 4: ( a ) D f 1 ( b ) D Ptie 12 and ( c ) D f 2 .
Figure 10 Responses for case 4: ( a ) D f 1 ( b ) D Ptie 12 and ( c ) D f 2 .CC-BY · From the PDF
Figure 11 Responses for case 5: ( a ) Δ f 1 ( b ) Δ P tie12 and ( c ) Figure 11. Responses for case 5: ( a ) D f 1 ( b ) D Ptie 12 and ( c ) D f 2 .
Figure 11 Responses for case 5: ( a ) Δ f 1 ( b ) Δ P tie12 and ( c ) Figure 11. Responses for case 5: ( a ) D f 1 ( b ) D Ptie 12 and ( c ) D f 2 .CC-BY · From the PDF
Image 13
CC-BY · From the PDF
Figure 13 Responses for case 6 for variations in the tie-line coefficient: ( a ) D f 1 ( b ) D Ptie 12 and ( c ) D f 2 .
Figure 13 Responses for case 6 for variations in the tie-line coefficient: ( a ) D f 1 ( b ) D Ptie 12 and ( c ) D f 2 .CC-BY · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 27 references

Cited by

See all 62

Metadata

Authors
Kalyan, C., Goud, B., Reddy, C., Ramadan, H., Bajaj, M., & Ali, Z.
Affiliations
  • Vasireddy Venkatadri International Technological University (IN)
  • Department of Electrical Engineering, Anurag College of Engineering Ghatkesar, Telangana 501301, India
  • Department of Electrical Engineering, Malla Reddy Engineering College (A) Maisammaguda, Telangana 500100, India
  • Zagazig University (EG)
  • National Institute of Technology Delhi (IN)
  • Prince Sattam Bin Abdulaziz University (SA)
Corresponding author
Ali, Ziad
Venue
Energies
Publisher
MDPI AG
Published
2021-08-30
Volume
14
Issue
17
Pages
5387
ISSN
1996-1073 (ISSN-L)
OpenAlex
W3197065771
Cited by
61
References
28
Citations by year
2026: 7 · 2025: 17 · 2024: 8 · 2023: 14 · 2022: 13 · 2021: 2
FWCI
2.72
Type
journal article
Language
en
Open access
Locations
  • Energies (publishedVersion, cc-by)
  • RePEc: Research Papers in Economics (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Frequency Control in Power Systems
  • Physical Sciences › Engineering › Control and Systems Engineering › Advanced Control Systems Design
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Power System Optimization and Stability
Keywords
load frequency control, water cycle algorithm, interconnected power systems, communication delay, generation rate constraint, superconducting magnetic energy storage, unified power flow controller, ITAE index, step load disturbance, hydrothermal power systems, secondary frequency control, controller robustness

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Water Cycle Algorithm Optimized Type II Fuzzy Controller for Load Frequency Control of a Multi-Area, Multi-Fuel System with Communication Time Delays. https://app.cochat.ai/papers/10.3390/en14175387
The paper
Kalyan, C., Goud, B., Reddy, C., Ramadan, H., Bajaj, M., & Ali, Z. (2021). Water Cycle Algorithm Optimized Type II Fuzzy Controller for Load Frequency Control of a Multi-Area, Multi-Fuel System with Communication Time Delays. Energies. https://doi.org/10.3390/en14175387

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.