The DOI matches its Crossref record.
Energy-Efficient Thermal-Aware Task Scheduling for Homogeneous High-Performance Computing Data Centers: A Cyber-Physical Approach
Abstract
High-performance computing data centers have been rapidly growing, both in number and size. Thermal management of data centers can address dominant problems associated with cooling such as the recirculation of hot air from the equipment outlets to their inlets and the appearance of hot spots. In this paper, we show through formalization that minimizing the peak inlet temperature allows for the lowest cooling power needs. Using a low-complexity linear heat recirculation model, we define the problem of minimizing the peak inlet temperature within a data center through task assignment (MPIT-TA), consequently leading to minimal cooling-requirement. We also provide two methods to solve the formulation: Xlnt-GA, which uses a genetic algorithm, and Xlnt-SQP, which uses sequential quadratic programming. Results from small-scale data center simulations show that solving the formulation leads to an inlet temperature distribution that, compared to other approaches, is 2 degC to 5 degC lower and achieves about 20 to 30 percent cooling energy savings at common data center utilization rates. Moreover, our algorithms consistently outperform the minimize heat recirculation algorithm, a recirculation-reducing task placement algorithm in the literature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A survey of Cyber-Physical Systems
Shi, J., Wan, J., Yan, H., & Suo, H. (2011) · 2011 International Conference on Wireless Communications and Signal Processing (WCSP) · doi:10.1109/wcsp.2011.6096958 · Cited by 608
Big data analytics for dynamic energy management in smart grids
Diamantoulakis, P. D., Kapinas, V. M., & Karagiannidis, G. K. (2015) · Big Data Research · doi:10.1016/j.bdr.2015.03.003 · Cited by 349
DENS: Data Center Energy-Efficient Network-Aware Scheduling
Kliazovich, D., Bouvry, P., & Khan, S. U. (2010) · 2010 IEEE/ACM Int'l Conference on Green Computing and Communications & Int'l Conference on Cyber, Physical and Social Computing · doi:10.1109/greencom-cpscom.2010.31 · Cited by 239
Metadata
- Authors
- Tang, Q., Gupta, S. K. S., & Varsamopoulos, G.
- Venue
- IEEE Transactions on Parallel and Distributed Systems
- Published
- 2008-11
- Volume
- 19
- Issue
- 11
- Pages
- 1458-1472
- ISSN
- 1045-9219 (ISSN-L)
- 1558-2183
- 2161-9883
- OpenAlex
- W2106119405
- Cited by
- 481
- References
- 0
- FWCI
- 68.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Energy-Efficient Thermal-Aware Task Scheduling for Homogeneous High-Performance Computing Data Centers: A Cyber-Physical Approach. https://app.cochat.ai/papers/10.1109/tpds.2008.111
- The paper
- Tang, Q., Gupta, S. K. S., & Varsamopoulos, G. (2008). Energy-Efficient Thermal-Aware Task Scheduling for Homogeneous High-Performance Computing Data Centers: A Cyber-Physical Approach. IEEE Transactions on Parallel and Distributed Systems. https://doi.org/10.1109/tpds.2008.111
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.