The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Energy-Efficient Thermal-Aware Task Scheduling for Homogeneous High-Performance Computing Data Centers: A Cyber-Physical Approach
Abstract
High-performance computing data centers have been rapidly growing, both in number and size. Thermal management of data centers can address dominant problems associated with cooling such as the recirculation of hot air from the equipment outlets to their inlets and the appearance of hot spots. In this paper, we show through formalization that minimizing the peak inlet temperature allows for the lowest cooling power needs. Using a low-complexity linear heat recirculation model, we define the problem of minimizing the peak inlet temperature within a data center through task assignment (MPIT-TA), consequently leading to minimal cooling-requirement. We also provide two methods to solve the formulation: Xlnt-GA, which uses a genetic algorithm, and Xlnt-SQP, which uses sequential quadratic programming. Results from small-scale data center simulations show that solving the formulation leads to an inlet temperature distribution that, compared to other approaches, is 2 degC to 5 degC lower and achieves about 20 to 30 percent cooling energy savings at common data center utilization rates. Moreover, our algorithms consistently outperform the minimize heat recirculation algorithm, a recirculation-reducing task placement algorithm in the literature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Genetic Algorithms + Data Structures = Evolution Programs
Michalewicz, Z. (1992) · Artificial Intelligence · doi:10.1007/978-3-662-02830-8 · Cited by 11,553
Genetic Algorithms + Data Structures = Evolution Programs
Michalewicz, Z. (1994) · Springer eBooks · doi:10.1007/978-3-662-07418-3 · Cited by 2,158
Making scheduling cool: temperature-aware workload placement in data centers
Moore, J., Chase, J., Ranganathan, P., & Sharma, R. K. (2005) · USENIX Annual Technical Conference · Cited by 651
Managing server energy and operational costs in hosting centers
Chen, Y., Das, A., Qin, W., Sivasubramaniam, A., Wang, Q., & Gautam, N. (2005) · Proceedings of the 2005 ACM SIGMETRICS international conference on Measurement and modeling of computer systems · doi:10.1145/1064212.1064253 · Cited by 556
Ensemble-level Power Management for Dense Blade Servers
Ranganathan, P., Leech, P., Irwin, D., & Chase, J. (2006) · ACM SIGARCH Computer Architecture News · doi:10.1145/1150019.1136492 · Cited by 357
Energy conservation in heterogeneous server clusters
Heath, T., Diniz, B., Carrera, E. V., Meira, W., & Bianchini, R. (2005) · Proceedings of the tenth ACM SIGPLAN symposium on Principles and practice of parallel programming · doi:10.1145/1065944.1065969 · Cited by 329
Ensemble-level Power Management for Dense Blade Servers
Ranganathan, P., Leech, P., Irwin, D., & Chase, J. S. (2006) · Proceedings - International Symposium on Computer Architecture/Proceedings · doi:10.1109/isca.2006.20 · Cited by 242
Sensor-Based Fast Thermal Evaluation Model For Energy Efficient High-Performance Datacenters
Tang, Q., Mukherjee, T., Gupta, S. K. S., & Cayton, P. (2006) · 2006 Fourth International Conference on Intelligent Sensing and Information Processing · doi:10.1109/icisip.2006.4286097 · Cited by 206
Self-citationWeatherman: Automated, Online and Predictive Thermal Mapping and Management for Data Centers
Moore, J., Chase, J. S., & Ranganathan, P. (2006) · 2006 IEEE International Conference on Autonomic Computing · doi:10.1109/icac.2006.1662394 · Cited by 205
Mercury and freon: temperature emulation and management for server systems
Heath, T., Centeno, A. P., George, P., Ramos, L., Jaluria, Y., & Bianchini, R. (2006) · Proceedings of the 12th international conference on Architectural support for programming languages and operating systems · doi:10.1145/1168857.1168872 · Cited by 199
Cited by
Habibi Khalaj, A., & Halgamuge, S. K. (2017) · Applied Energy · doi:10.1016/j.apenergy.2017.08.037 · Cited by 707
Energy efficient utilization of resources in cloud computing systems
Lee, Y. C., & Zomaya, A. Y. (2012) · The Journal of Supercomputing · doi:10.1007/s11227-010-0421-3 · Cited by 647
A survey of Cyber-Physical Systems
Shi, J., Wan, J., Yan, H., & Suo, H. (2011) · 2011 International Conference on Wireless Communications and Signal Processing (WCSP) · doi:10.1109/wcsp.2011.6096958 · Cited by 608
Multi-Objective Virtual Machine Placement in Virtualized Data Center Environments
Xu, J., & Fortes, J. A. B. (2010) · 2010 IEEE/ACM Int'l Conference on Green Computing and Communications & Int'l Conference on Cyber, Physical and Social Computing · doi:10.1109/greencom-cpscom.2010.137 · Cited by 529
Optimizing energy consumption for data centers
Rong, H., Zhang, H., Xiao, S., Li, C., & Hu, C. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.12.283 · Cited by 398
A survey and taxonomy on energy efficient resource allocation techniques for cloud computing systems
Hameed, A., Khoshkbarforoushha, A., Ranjan, R., Jayaraman, P. P., Kolodziej, J., Balaji, P., Zeadally, S., Malluhi, Q. M., Tziritas, N., Vishnu, A., et al. (2016) · Computing · doi:10.1007/s00607-014-0407-8 · Cited by 376
Big data analytics for dynamic energy management in smart grids
Diamantoulakis, P. D., Kapinas, V. M., & Karagiannidis, G. K. (2015) · Big Data Research · doi:10.1016/j.bdr.2015.03.003 · Cited by 349
Ensuring Safety, Security, and Sustainability of Mission-Critical Cyber–Physical Systems
Banerjee, A., Venkatasubramanian, K. K., Mukherjee, T., & Gupta, S. K. S. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2011.2165689 · Cited by 318
Self-citationDENS: Data Center Energy-Efficient Network-Aware Scheduling
Kliazovich, D., Bouvry, P., & Khan, S. U. (2010) · 2010 IEEE/ACM Int'l Conference on Green Computing and Communications & Int'l Conference on Cyber, Physical and Social Computing · doi:10.1109/greencom-cpscom.2010.31 · Cited by 239
Metadata
- Authors
- Tang, Q., Gupta, S. K. S., & Varsamopoulos, G.
- Venue
- IEEE Transactions on Parallel and Distributed Systems
- Published
- 2008-11
- Volume
- 19
- Issue
- 11
- Pages
- 1458-1472
- ISSN
- 1045-9219 (ISSN-L)
- 1558-2183
- 2161-9883
- OpenAlex
- W2106119405
- Cited by
- 481
- References
- 15
- FWCI
- 68.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.