Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Analysis and Mitigation of Power System Harmonics in Industrial Vfd Applications Using Passive Filter Configurations

Abstract

This paper investigates harmonic mitigation techniques for an industrial distribution network supplying VFD-driven loads. A MATLAB-Simulink model evaluates passive filter configurations, tuning frequency, quality factor, and filter placement. Results show substantial reductions in current and voltage THD and compliance with IEEE 519-2022 limits.

Overview

Integrity signals

Registry

Crossref · 10.1109/tpec67884.2026.11513162

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 7 references

Research works printed but not linked: 8

  1. Math HJ, 2006, Signal processing of power quality disturbances
  2. Adis, Measuring and Modeling VFDs Harmonics in Pump Application with Matlab/Simulink By Using Low Voltage R and L Parameters of the Power Grid, 340
  3. Roberto, 2014, IEEE recommended practice and requirements for harmonic control in electric power systems, IEEE recommended practice
  4. Jos, 2004, Power system harmonics
  5. 2020, IEC 61000-3-12: Limits for Harmonic Currents Produced by Equipment Connected to Public Low-Voltage Systems with Input Current $>16$ A and $\leq 75 A$ per phase, International Electrotechnical Commission (IEC), Geneva, Switzerland
  6. 2022, IEC 61800-3: Adjustable speed electrical power drive systems-Part 3: EMC requirements and specific test methods for power drive systems, IEC
  7. Ned, 2003, Power electronics: converters, applications, and design
  8. Math HJ, 2006, Signal processing of power quality disturbances

Metadata

Authors
Munsi, M. S., Alao, A. B., Dasari, B. K., Tadese, Y. B., Dhakal, B., Chamana, M., Adeyanju, O. M., & Bayne, S.
Affiliations
Texas Tech University (US)
Venue
2026 IEEE Texas Power and Energy Conference (TPEC)
Publisher
IEEE
Published
2026-02-09
Pages
1-6
OpenAlex
W7161235563
Cited by
0
References
7
FWCI
0.00
Type
conference paper
Language
en
Open access
closed
Locations
IEEE Texas Power and Energy Conference (TPEC) (publishedVersion)
Funders
Department of Energy (DE-CR0000038)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electromagnetic Compatibility and Noise Suppression
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
Keywords
power system harmonics, harmonic compensation, passive filters, variable frequency drive, nonlinear loads, total harmonic distortion, filter placement, quality factor, parallel transformers, industrial distribution networks, power quality, resonance

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Analysis and Mitigation of Power System Harmonics in Industrial Vfd Applications Using Passive Filter Configurations. https://app.cochat.ai/papers/10.1109/tpec67884.2026.11513162
The paper
Munsi, M. S., Alao, A. B., Dasari, B. K., Tadese, Y. B., Dhakal, B., Chamana, M., Adeyanju, O. M., & Bayne, S. (2026). Analysis and Mitigation of Power System Harmonics in Industrial Vfd Applications Using Passive Filter Configurations. 2026 IEEE Texas Power and Energy Conference (TPEC). https://doi.org/10.1109/tpec67884.2026.11513162

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.