The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Three-dimensional space vector modulation for four-leg voltage-source converters
Abstract
Four-leg voltage-source converters can effectively provide the neutral connection in three-phase four-wire systems. They can be used in inverter, rectifier, and active filter applications to handle the neutral current caused by the unbalanced and/or nonlinear load or unbalanced source. In this paper, three-dimensional (3-D) space vector modulation (SVM) schemes are proposed for controlling the four-leg voltage-source converters. Important issues for 3-D SVM, such as definition of 3-D vectors, identification of adjacent switching vectors in the 3-D space, and switching vector sequencing schemes and comparisons are addressed. The proposed 3-D SVM is a superset of the traditional two-dimensional (2-D) SVM, and thus it inherits all the merits of the traditional 2-D SVM. A 100 kW 5 kHz four-leg inverter and a 20 kHz four-leg rectifier prototypes are built and controlled by the proposed 3-D SVM. Experimental results are presented to validate the effectiveness of the 3-D SVM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Influence of the modulation method on the conduction and switching losses of a PWM converter system
Kolar, J. W., Ertl, H., & Zach, F. C. (1991) · IEEE Transactions on Industry Applications · doi:10.1109/28.108456 · Cited by 548
On continuous control of PWM inverters in the overmodulation range including the six-step mode
Holtz, J., Lotzkat, W., & Khambadkone, A. (2003) · Proceedings of the 1992 International Conference on Industrial Electronics, Control, Instrumentation, and Automation · doi:10.1109/iecon.1992.254615 · Cited by 364
Four-legged three-phase PFC rectifier with fault tolerant capability
Zhang, R., Lee, F. C., & Boroyevich, D. (2002) · PESC record · doi:10.1109/pesc.2000.878878 · Cited by 44
Self-citationSlazar, L. S., Zapata, F. F., & Wiechmann, E. P. (2002) · PESC record · doi:10.1109/pesc.1997.616767 · Cited by 8
Cited by
Multilevel Converters: An Enabling Technology for High-Power Applications
Rodriguez, J., Franquelo, L. G., Kouro, S., Leon, J. I., Portillo, R. C., Prats, M. A. M., & Perez, M. A. (2009) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2030235 · Cited by 1,196
Haque, M. M., & Wolfs, P. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.04.025 · Cited by 331
A carrier-based PWM method for three-phase four-leg voltage source converters
Kim, J.-H., & Sul, S.-K. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.820559 · Cited by 264
Power converter interfaces for electrochemical energy storage systems – A review
Fernão Pires, V., Romero-Cadaval, E., Vinnikov, D., Roasto, I., & Martins, J. F. (2014) · Energy Conversion and Management · doi:10.1016/j.enconman.2014.05.003 · Cited by 254
A novel three-phase four-leg inverter based load unbalance compensator for stand-alone microgrid
Kim, G.-H., Hwang, C., Jeon, J.-H., Ahn, J.-B., & Kim, E.-S. (2015) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2014.09.035 · Cited by 41
Metadata
- Authors
- Zhang, R., Prasad, V. H., Boroyevich, D., & Lee, F. C.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2002-05
- Volume
- 17
- Issue
- 3
- Pages
- 314-326
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2121920897
- Cited by
- 494
- References
- 4
- FWCI
- 15.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.