Cited by 41Microgrid Control and OptimizationPower Quality and HarmonicsMultilevel Inverters and Converters

The DOI matches its Crossref record.

A novel three-phase four-leg inverter based load unbalance compensator for stand-alone microgrid

Open access
Kim, Gyeong-Hun, Hwang, Chulsang, Jeon, Jin-Hong, Ahn, Jong-Bo, Kim, Eung-Sang·2015·International Journal of Electrical Power & Energy Systems

Abstract

This paper proposes a three-phase four-leg voltage sourced inverter (VSI) based load unbalance compensator (LUC) including its control algorithm, which is a component of a microgrid. The purpose of proposed three-phase four-leg VSI based LUC is to improve power quality of the standalone microgrid. Power quality of the microgrid which was installed in Mara-island, Korea is analyzed using a real operational data. In this work, the microgrid in Mara-island which includes a photovoltaic power generation system, a diesel generator, a battery energy storage system, and a power management system is modeled in PSCAD/EMTDC, and proposed three-phase four-leg VSI based LUC is also modeled and applies to the modeled microgrid. Power flow and stability of the modeled microgrid with the LUC is analyzed under variable irradiance and unbalance loads. The results show that the proposed LUC helps to improve stability of the stand-alone microgrid. The proposed three-phase four-leg VSI based LUC and its control algorithm can be effectively utilized to the stand alone microgrid which has large unbalance loads.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ijepes.2014.09.035

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 21

  1. Habibi, 2013, Electr Power Energy Syst, 44, 656, 10.1016/j.ijepes.2012.08.023 · DOI
  2. Al-Saedi, 2013, Electr Power Energy Syst, 42, 139, 10.1016/j.ijepes.2012.04.007 · DOI
  3. Huang, 2013, Electr Power Energy Syst, 43, 1127, 10.1016/j.ijepes.2012.06.068 · DOI
  4. Al-Saedi, 2013, Electr Power Energy Syst, 49, 76, 10.1016/j.ijepes.2012.12.017 · DOI
  5. Katiraei, 2008, IEEE Power Energy Mag, 54, 10.1109/MPE.2008.918702 · DOI
  6. Bauer P, Weldemariam LE, Raijen E. In: IEEE 33rd international telecommunications energy conference; 2011. p. 1–10. · DOI
  7. Hatziargyriou, 2007, IEEE Power Energy Mag, 78, 10.1109/MPAE.2007.376583 · DOI
  8. Shahnia, 2010, Electr Power Syst Res, 80, 954, 10.1016/j.epsr.2010.01.005 · DOI
  9. Griffiths M, Coates C. In: Power engineering conference; 2007. p. 1–5. · DOI
  10. Vo, 2013, Int J Emerging Technol Adv Eng, 3, 536
  11. Cheng, 2009, IEEE Trans Ind Appl, 45, 805, 10.1109/TIA.2009.2013601 · DOI
  12. Savaghebi, 2013, IEEE Trans Ind Electron, 60, 1390, 10.1109/TIE.2012.2185914 · DOI
  13. Hamzeh, 2012, IEEE Trans Power Syst, 27, 2225, 10.1109/TPWRS.2012.2193906 · DOI
  14. Li, 2005, IEEE Trans Ind Appl, 41, 1707, 10.1109/TIA.2005.858262 · DOI
  15. Savaghebi, 2012, IEEE Trans Smart Grid, 3, 797, 10.1109/TSG.2011.2181432 · DOI
  16. Ngamroo, 2012, Electr Power Energy Syst, 43, 969, 10.1016/j.ijepes.2012.05.051 · DOI
  17. Wichert, 1997, Renew Sustain Energy Rev, 3, 209, 10.1016/S1364-0321(97)00006-3 · DOI
  18. Tan, 2013, Electr Power Energy Syst, 44, 179, 10.1016/j.ijepes.2012.07.015 · DOI
  19. Liu, 2012, Energy Procedia, 16, 1822, 10.1016/j.egypro.2012.01.280 · DOI
  20. Kim, 2004, IEEE Trans Power Electron, 19, 66, 10.1109/TPEL.2003.820559 · DOI
  21. Zhang, 2002, IEEE Trans Power Electron, 17, 314, 10.1109/TPEL.2002.1004239 · DOI

Cited by

Sorted by citations

See all 41

Metadata

Authors
Kim, G.-H., Hwang, C., Jeon, J.-H., Ahn, J.-B., & Kim, E.-S.
Affiliations
Korea Electrotechnology Research Institute (KR)
Corresponding author
Kim, Gyeong-Hun
Venue
International Journal of Electrical Power & Energy Systems
Publisher
Elsevier BV
Published
2015-02
Volume
65
Pages
70-75
ISSN
0142-0615 (ISSN-L)
OpenAlex
W2082593246
Cited by
41
References
0
Citations by year
2026: 3 · 2025: 4 · 2024: 1 · 2023: 3 · 2022: 2 · 2021: 2 · 2020: 6 · 2019: 5 · 2018: 2 · 2017: 3 · 2016: 5 · 2015: 5
FWCI
4.83
Type
journal article
Language
en
Open access
Locations
International Journal of Electrical Power & Energy Systems (publishedVersion, cc-by-nc-nd)
Topics
  • Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
Keywords
three-phase four-leg inverter, stand-alone microgrid, power quality, unbalanced loads, photovoltaic power generation, battery energy storage, diesel generator, power management system, microgrid stability, irradiance variation, control algorithms

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A novel three-phase four-leg inverter based load unbalance compensator for stand-alone microgrid. https://app.cochat.ai/papers/10.1016/j.ijepes.2014.09.035
The paper
Kim, G.-H., Hwang, C., Jeon, J.-H., Ahn, J.-B., & Kim, E.-S. (2015). A novel three-phase four-leg inverter based load unbalance compensator for stand-alone microgrid. International Journal of Electrical Power & Energy Systems. https://doi.org/10.1016/j.ijepes.2014.09.035