Configurable front-end converters for multicurrent locomotives operated on 16 2/3 Hz AC and 3 kV DC systems
Open accessThe DOI matches its Crossref record.
Abstract
A configurable converter topology is presented as front-end converter for a locomotive that can be operated as well on a high voltage AC-system as on a medium voltage DC-system. The configurable converter is realized on the base of a multilevel chain, where all modules are fed through reversible and isolated DC-DC stages. The medium frequency transformers used in the isolation stages of the DC-DC converters allow a significant weight reduction of the locomotive, in comparison with the classical low-frequency voltage-transformers. A first solution using hard switching techniques is presented, using a three-times silicon-conversion. A second solution based on ZVT/ZCS techniques is then presented, with the advantage of having ideally only a two times silicon conduction. Prototype modules have been realized with association of diodes and IGBTs in order to provide reverse-blocking devices. First results of the two-stage conversion are also presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Power Electronic Traction Transformer—Medium Voltage Prototype
Zhao, C., Dujic, D., Mester, A., Steinke, J. K., Weiss, M., Lewdeni-Schmid, S., Chaudhuri, T., & Stefanutti, P. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2278960 · Cited by 478
Power Electronic Traction Transformer-Low Voltage Prototype
Dujic, D., Zhao, C., Mester, A., Steinke, J. K., Weiss, M., Lewdeni-Schmid, S., Chaudhuri, T., & Stefanutti, P. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2248756 · Cited by 293
Garcia-Bediaga, A., Villar, I., Rujas, A., Mir, L., & Rufer, A. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2574499 · Cited by 126
Self-citationMultilevel Converter for Traction Applications: Small-Scale Prototype Tests Results
Carpita, M., Marchesoni, M., Pellerin, M., & Moser, D. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.918645 · Cited by 100
“From this basic module, a multilevel solution was proposed for naval and traction applications [14]–[16].”
Krishnamoorthy, H. S., Rana, D., Garg, P., Enjeti, P. N., & Pitel, I. J. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2295419 · Cited by 48
A Leakage-Inductance-Tolerant Commutation Strategy for Isolated AC/AC Converters
Nasir, U., Costabeber, A., Rivera, M., Wheeler, P., & Clare, J. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2861326 · Cited by 35
“The opportunity to shape these scenarios for SSTs comes, for example, from future distribution systems [6] and new traction systems [5, 7].”
BackgroundSiC-Based Power Electronic Traction Transformer (PETT) for 3 kV DC Rail Traction
Adamowicz, M., & Szewczyk, J. (2020) · Energies · doi:10.3390/en13215573 · Cited by 24
“The DC PETT described in [14] provides a higher quality of drive operation during DC voltage disturbances which normally occur in 3 kV DC traction, than conventional propulsion systems with two-level and three-level inverters.”
BackgroundInfluential
Metadata
- Authors
- Rufer, A., Schibli, N., Chabert, C., & Zimmermann, C.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2003-09
- Volume
- 18
- Issue
- 5
- Pages
- 1186-1193
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2106572889
- Cited by
- 60
- References
- 0
- FWCI
- 1.01
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.