An Adaptive Dead-Time Compensation Strategy for Voltage Source Inverter Fed Motor Drives
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
This paper presents an adaptive dead-time compensation strategy to obtain fundamental phase voltage for inverter fed vector controlled permanent magnet synchronous motor drives. The amplitude of phase dead-time compensation voltage (DTCV) to compensate disturbance voltage due to undesirable characteristics of inverter, such as dead-time, turn-on/off time of switching devices, and on-voltages of switching devices and diodes is adaptively determined according to a dead-time compensation time (DTCT). DTCT is identified on-line with using a /spl delta/-axis disturbance voltage in the current reference frame that is synchronized with current vector. The /spl delta/-axis disturbance voltage is estimated by a disturbance observer. The accuracy of identified DTCT is experimentally confirmed by calculating the mean absolute percentage error (MAPE) between a calculated active power and a measured one. MAPE for adaptive DTCT is almost within 5% at any operating point.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of direct torque control in permanent magnet synchronous motor drives
Zhong, L., Rahman, M. F., Hu, W. Y., & Lim, K. W. (1997) · IEEE Transactions on Power Electronics · doi:10.1109/63.575680 · Cited by 951 · cited 1×
“Several applications, such as rotor position sensorless drives strategy [1], [2] and direct torque control strategy [3] need information on fundamental phase voltage.”
BackgroundInverter output voltage synthesis using novel dead time compensation
Choi, J.-W., & Sul, S.-K. (1996) · IEEE Transactions on Power Electronics · doi:10.1109/63.486169 · Cited by 509
Holtz, J., & Quan, J. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2002.800779 · Cited by 376 · cited 1×
“Several applications, such as rotor position sensorless drives strategy [1], [2] and direct torque control strategy [3] need information on fundamental phase voltage.”
BackgroundHoltz, J., & Quan, J. (2002) · Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248) · doi:10.1109/ias.2001.955988 · Cited by 354
Inverter nonlinearities and discrete-time vector current control
Sepe, R. B., & Lang, J. H. (1994) · IEEE Transactions on Industry Applications · doi:10.1109/28.273622 · Cited by 103
Cited by
Digital Control in Power Electronics
Buso, S., & Mattavelli, P. (2006) · Synthesis lectures on power electronics · doi:10.2200/s00047ed1v01y200609pel002 · Cited by 535
Cost-Effective Three-Phase PMSM Drive Tolerant to Open-Phase Fault
Kontarcek, A., Bajec, P., Nemec, M., Ambrozic, V., & Nedeljkovic, D. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2437357 · Cited by 106
Metadata
- Authors
- Urasaki, N., Senjyu, T., Uezato, K., & Funabashi, T.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2005-09
- Volume
- 20
- Issue
- 5
- Pages
- 1150-1160
- ISSN
- 0885-8993 (ISSN-L)
- OpenAlex
- W2107463151
- Cited by
- 183
- References
- 5
- FWCI
- 5.72
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.