The DOI matches its Crossref record.
Current Control Strategy for Power Conditioners Using Sinusoidal Signal Integrators in Synchronous Reference Frame
Abstract
In this paper, a current control scheme, based on proportional-integral regulators using sinusoidal signal integrators (SSIs), is proposed for shunt type power conditioners. The aim is to simplify the implementation of SSI-based current harmonic compensation for industrial implementations where strict limitations on the harmonic distortion of the mains' currents are required. To compensate current harmonics, the SSIs are implemented to operate both on positive and negative sequence signals. One regulator, for the fundamental current component, is implemented in the stationary reference frame. The other regulators, for the current harmonics, are all implemented in a synchronous reference frame rotating at the fundamental frequency. This allows the simultaneous compensation of two current harmonics with just one regulator, yielding a significant reduction of the computational effort compared with other current control methods employing sinusoidal signal integrators implemented in stationary reference frame. A simple and robust voltage filter is also proposed by the authors to obtain a smooth and accurate position estimation of the voltage vector at the point of common coupling (PCC) under distorted mains' voltages. The whole control algorithm has been implemented on a 16-b, fixed-point digital signal processor (DSP) platform controlling a 20-kVA power conditioner prototype. The experimental results presented in this paper for inductive and capacitive loads show the validity of the proposed solutions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Proportional-resonant controllers and filters for grid-connected voltage-source converters
Teodorescu, R., Blaabjerg, F., Liserre, M., & Loh, P. C. (2006) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:20060008 · Cited by 1,646
Current Limiting Control With Enhanced Dynamics of Grid-Forming Converters During Fault Conditions
Taul, M. G., Wang, X., Davari, P., & Blaabjerg, F. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2931477 · Cited by 466
Rana, R. A., Patel, S. A., Muthusamy, A., Lee, C. W., & Kim, H.-J. (2019) · Electronics · doi:10.3390/electronics8111329 · Cited by 102
Metadata
- Authors
- Bojoi, R. I., Griva, G., Bostan, V., Guerriero, M., Farina, F., & Profumo, F.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2005-11
- Volume
- 20
- Issue
- 6
- Pages
- 1402-1412
- ISSN
- 0885-8993 (ISSN-L)
- OpenAlex
- W2171417678
- Cited by
- 397
- References
- 0
- FWCI
- 8.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Current Control Strategy for Power Conditioners Using Sinusoidal Signal Integrators in Synchronous Reference Frame. https://app.cochat.ai/papers/10.1109/tpel.2005.857558
- The paper
- Bojoi, R. I., Griva, G., Bostan, V., Guerriero, M., Farina, F., & Profumo, F. (2005). Current Control Strategy for Power Conditioners Using Sinusoidal Signal Integrators in Synchronous Reference Frame. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2005.857558
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.