Abstract
In this paper, a new control method for the parallel operation of inverters operating in an island grid or connected to an infinite bus is described. Frequency and voltage control, including mitigation of voltage harmonics, are achieved without the need for any common control circuitry or communication between inverters. Each inverter supplies a current that is the result of the voltage difference between a reference ac voltage source and the grid voltage across a virtual complex impedance. The reference ac voltage source is synchronized with the grid, with a phase shift, depending on the difference between rated and actual grid frequency. A detailed analysis shows that this approach has a superior behavior compared to existing methods, regarding the mitigation of voltage harmonics, short-circuit behavior and the effectiveness of the frequency and voltage control, as it takes the R to X line impedance ratio into account. Experiments show the behavior of the method for an inverter feeding a highly nonlinear load and during the connection of two parallel inverters in operation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Olivares, D. E., Mehrizi-Sani, A., Etemadi, A. H., Canizares, C. A., Iravani, R., Kazerani, M., Hajimiragha, A. H., Gomis-Bellmunt, O., Saeedifard, M., Palma-Behnke, R., et al. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2295514 · Cited by 3,137
He, J., & Li, Y. W. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2168592 · Cited by 759
Voltage Fluctuations on Distribution Level Introduced by Photovoltaic Systems
Woyte, A., Thong, V. V., Belmans, R., & Nijs, J. (2006) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.845454 · Cited by 482
Self-citationImprovement of Frequency Regulation in VSG-Based AC Microgrid Via Adaptive Virtual Inertia
Hou, X., Sun, Y., Zhang, X., Lu, J., Wang, P., & Guerrero, J. M. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2923734 · Cited by 367
A Cooperative Imbalance Compensation Method for Distributed-Generation Interface Converters
Cheng, P.-T., Chen, C.-A., Lee, T.-L., & Kuo, S.-Y. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2013601 · Cited by 253
Metadata
- Authors
- De Brabandere, K., Bolsens, B., Van den Keybus, J., Woyte, A., Driesen, J., & Belmans, R.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2007-07
- Volume
- 22
- Issue
- 4
- Pages
- 1107-1115
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2108326722
- Cited by
- 1,865
- References
- 0
- FWCI
- 104.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Voltage and Frequency Droop Control Method for Parallel Inverters. https://app.cochat.ai/papers/10.1109/tpel.2007.900456
- The paper
- De Brabandere, K., Bolsens, B., Van den Keybus, J., Woyte, A., Driesen, J., & Belmans, R. (2007). A Voltage and Frequency Droop Control Method for Parallel Inverters. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2007.900456
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.