The Short-Time-Scale Transient Processes in High-Voltage and High-Power Isolated Bidirectional DC–DC Converters
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper discusses the short-time-scale transient processes in an isolated bidirectional dc-dc converter with phase-shift control. The deadband effect on the steady-state and transient commutating process are analyzed. The current variations caused by phase-shift errors at the boundary conditions are simulated and validated through experiments. The concept of ldquoenergy deadbandrdquo is introduced to describe those specific transients where no energy flows from source to load or load to source. A set of strategies are proposed to increase the system robustness. Simulation and experiments on a 200-V/400-V, 6-kW DC-DC converter prototype validated these strategies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A natural ZVS medium-power bidirectional DC-DC converter with minimum number of devices
Li, H., Peng, F. Z., & Lawler, J. S. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.808965 · Cited by 296 · cited 2×
“The previous works on the full-bridge dc–dc converter mainly focused on the topology [5], [6], control strategies [7], [8], and macroscopic modeling methods [9]–[12] based on classical control theory.”
BackgroundMethod
Cited by
Zhao, B., Song, Q., Liu, W., & Sun, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2289913 · Cited by 1,886
Efficiency-Optimized High-Current Dual Active Bridge Converter for Automotive Applications
Krismer, F., & Kolar, J. W. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2112312 · Cited by 747
Generalized Average Modeling of Dual Active Bridge DC–DC Converter
Qin, H., & Kimball, J. W. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2165734 · Cited by 557
Analysis and Design of High-Frequency Isolated Dual-Bridge Series Resonant DC/DC Converter
Li, X., & Bhat, A. K. S. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2034662 · Cited by 493
Modeling and Advanced Control of Dual-Active-Bridge DC–DC Converters: A Review
Shao, S., Chen, L., Shan, Z., Gao, F., Chen, H., Sha, D., & Dragičević, T. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3108157 · Cited by 488
Metadata
- Authors
- Bai, H., Mi, C. C., & Gargies, S.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2008-11
- Volume
- 23
- Issue
- 6
- Pages
- 2648-2656
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2165258322
- Cited by
- 142
- References
- 1
- FWCI
- 6.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Short-Time-Scale Transient Processes in High-Voltage and High-Power Isolated Bidirectional DC–DC Converters. https://app.cochat.ai/papers/10.1109/tpel.2008.2005106
- The paper
- Bai, H., Mi, C. C., & Gargies, S. (2008). The Short-Time-Scale Transient Processes in High-Voltage and High-Power Isolated Bidirectional DC–DC Converters. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2008.2005106
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.