Voltage Balancing of a 320-V, 12-F Electric Double-Layer Capacitor Bank Combined With a 10-kW Bidirectional Isolated DC--DC Converter
The DOI matches its Crossref record.
Abstract
Electric double-layer capacitors (EDLCs) have attributes that feature high power density, quick charge/discharge time, long life cycle, and environmental friendliness. These attributes accord for increased appeal in employing the EDLCs as energy-storage devices in renewable energy systems, industrial applications, and hybrid electric vehicles as compared to other mature static energy-storage devices. This paper describes the construction of a 320-V, 12-F EDLC energy-storage bank connected to a bidirectional isolated dc-dc converter. Two types of EDLC bank configurations are considered with emphasis on their voltage-balancing circuits. Subsequently, this paper proposes a voltage-balancing circuit based on a center-tapped transformer, and includes its experimental verifications. It also discusses the charge-discharge and self-starting operation of the EDLC energy-storage system. During the charge-discharge operation, a low ripple current flowing in the EDLC bank is observed, leading to a theoretical analysis. The EDLC bank is also successfully charged to its rated voltage without any external dc charging circuit.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Energy Storage Systems for Transport and Grid Applications
Vazquez, S., Lukic, S. M., Galvan, E., Franquelo, L. G., & Carrasco, J. M. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2076414 · Cited by 1,347
Oggier, G. G., Garcia, G. O., & Oliva, A. R. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2072966 · Cited by 498
Tan, N. M. L., Abe, T., & Akagi, H. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2108317 · Cited by 490
Self-citationHigh-Power Bidirectional DC–DC Converter for Aerospace Applications
Naayagi, R. T., Forsyth, A. J., & Shuttleworth, R. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2184771 · Cited by 305
“Bidirectional power flow capability is a key feature of DAB dc–dc converters, permitting flexible interfacing to energy storage devices [15], [16].”
BackgroundAkagi, H., Kinouchi, S.-I., & Miyazaki, Y. (2016) · CPSS Transactions on Power Electronics and Applications · doi:10.24295/cpsstpea.2016.00004 · Cited by 84
Self-citation
Metadata
- Authors
- Tan, N. M. L., Inoue, S., Kobayashi, A., & Akagi, H.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2008-11
- Volume
- 23
- Issue
- 6
- Pages
- 2755-2765
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2113798850
- Cited by
- 98
- References
- 0
- FWCI
- 8.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Voltage Balancing of a 320-V, 12-F Electric Double-Layer Capacitor Bank Combined With a 10-kW Bidirectional Isolated DC--DC Converter. https://app.cochat.ai/papers/10.1109/tpel.2008.2005388
- The paper
- Tan, N. M. L., Inoue, S., Kobayashi, A., & Akagi, H. (2008). Voltage Balancing of a 320-V, 12-F Electric Double-Layer Capacitor Bank Combined With a 10-kW Bidirectional Isolated DC--DC Converter. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2008.2005388
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.