Low Voltage Ride Through of Wind Farms With Cage Generators: STATCOM Versus SVC

Molinas, M., Jon Are Suul, Undeland, T.·2008·IEEE Transactions on Power Electronics

Abstract

This paper analyzes the extent to which the low voltage ride through (LVRT) capability of wind farms using squirrel cage generators can be enhanced by the use of a STATCOM, compared to the thyristor controlled static var compensator (SVC). The transient stability margin is proposed as the indicator of LVRT capability. A simplified analytical approach based on torque-slip characteristics is first proposed to quantify the effect of the STATCOM and the SVC on the transient stability margin. Results from experiments with a STATCOM and a 7.5 kW induction machine emulating a wind turbine are used to validate the suggested analytical approach. Further verifications based on detailed time-domain simulations are also provided. Calculations, simulations and measurements confirm how the increased STATCOM rating can provide an increased transient stability margin and thus enhanced LVRT capability. Compared to the SVC, the STATCOM gives a larger contribution to the transient margin as indicated by both calculations and simulations. The inaccuracies introduced by neglecting the flux transients in the suggested approach are discussed and found reasonable for an estimation method when considering the simplicity compared to detailed time-domain simulation studies. A method for estimating the required rating of different compensation devices to ensure stability after a fault is suggested based on the same approach.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tpel.2008.921169

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 426

Metadata

Authors
Molinas, M., Suul, J. A., & Undeland, T.
Venue
IEEE Transactions on Power Electronics
Published
2008-05
Volume
23
Issue
3
Pages
1104-1117
ISSN
  • 0885-8993 (ISSN-L)
  • 1941-0107
OpenAlex
W2170026376
Cited by
426
References
12
FWCI
23.91
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Low Voltage Ride Through of Wind Farms With Cage Generators: STATCOM Versus SVC. https://app.cochat.ai/papers/10.1109/tpel.2008.921169
The paper
Molinas, M., Suul, J. A., & Undeland, T. (2008). Low Voltage Ride Through of Wind Farms With Cage Generators: STATCOM Versus SVC. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2008.921169

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.