The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Wind Energy System With Integrated Functions of Active Power Transfer, Reactive Power Compensation, and Voltage Conversion
Abstract
As the power of wind energy system increases, the control of their active and reactive power becomes increasingly more important from a system standpoint given that these are typical frequency and voltage control parameters. In this paper, a family of wind energy systems with integrated functions of active power transfer, reactive power compensation, and voltage conversion is proposed. The proposed wind energy systems using solid-state transformer (SST) can effectively suppress the voltage fluctuation caused by the transient nature of wind energy without additional reactive power compensator and, as such, may enable the large penetration of wind farm (WF) into the power grid. To this end, a simulation study for WF driven by squirrel-cage induction generators is presented to verify the effectiveness of the proposed system. In addition, a modular-type high-voltage and high-power three-phase SST topology is presented for the proposed system, and its basic building block, which is a single-phase SST, is analyzed. The functions of SST in the presented wind energy system are verified in a single-phase laboratory prototype with scaled-down experiments. Lastly, cost issue of the proposed technology is analyzed with comparison to the traditional one.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
The Future Renewable Electric Energy Delivery and Management (FREEDM) System: The Energy Internet
Huang, A. Q., Crow, M. L., Heydt, G. T., Zheng, J. P., & Dale, S. J. (2011) · Proceedings of the IEEE · doi:10.1109/jproc.2010.2081330 · Cited by 1,463 · cited 3×
“On the one hand, efforts are focused on topology investigation in this new technology for high-voltage and high-power application [12]–[15].”
BackgroundSelf-citationDynamic modeling of doubly fed induction generator wind turbines
Ekanayake, J. B., Holdsworth, L., Wu, X., & Jenkins, N. (2003) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2003.811178 · Cited by 733 · cited 1×
“Presently, there are three main WF architectures, namely, SCIG-based wind energy system [21], doubly fed induction generator (DFIG)-based wind energy system [22], and directly driven synchronous generator (DDSG)-based wind energy system [23], shown in Fig.”
BackgroundPwm control of dual active bridge: Comprehensive analysis and experimental verification
Jain, A. K., & Ayyanar, R. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2070519 · Cited by 567 · cited 1×
“Its dc/dc stage is embodied by a dual active bridge (DAB) converter, which represents the most attractive candidate for high-power applications requiring isolation, as it can perform zero-voltage switching in a wide operation range [25], [26].”
BackgroundKrismer, F., & Kolar, J. W. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2025284 · Cited by 470 · cited 1×
“Its dc/dc stage is embodied by a dual active bridge (DAB) converter, which represents the most attractive candidate for high-power applications requiring isolation, as it can perform zero-voltage switching in a wide operation range [25], [26].”
BackgroundGrid Integration of Large DFIG-Based Wind Farms Using VSC Transmission
Xu, L., Yao, L., & Sasse, C. (2007) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2007.901306 · Cited by 428
Low Voltage Ride Through of Wind Farms With Cage Generators: STATCOM Versus SVC
Molinas, M., Suul, J. A., & Undeland, T. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.921169 · Cited by 426
Fault-Tolerant Design and Control Strategy for Cascaded H-Bridge Multilevel Converter-Based STATCOM
Song, W., & Huang, A. Q. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2036019 · Cited by 358 · cited 1×
“redundant design can be incorporated to achieve fault-tolerant operation [27].”
BackgroundSelf-citationA power electronic-based distribution transformer
Ronan, E. R., Sudhoff, S. D., Glover, S. F., & Galloway, D. L. (2002) · IEEE Transactions on Power Delivery · doi:10.1109/61.997934 · Cited by 313
STATCOM Impact Study on the Integration of a Large Wind Farm into a Weak Loop Power System
Han, C., Huang, A. Q., Baran, M. E., Bhattacharya, S., Litzenberger, W., Anderson, L., Johnson, A. L., & Edris, A.-A. (2008) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2006.888031 · Cited by 307
Self-citationA Power Electronic-Based Distribution Transformer
Ronan, E. R., Sudhoff, S. D., Glover, S. F., & Galloway, D. L. (2002) · IEEE Power Engineering Review · doi:10.1109/mper.2002.4312081 · Cited by 264
Research works printed but not linked: 3
- 2011, Field Prototype Development of Intelligent Universal Transformer
- wang, 2011, Comparison of different control strategies for 20 KVA solid state transformer, Proc IEEE ECCE, 3173
- 2009, Wind Energy The Facts A Guide to the Technology Economics and Future of Wind Power
Cited by
Review of Solid-State Transformer Technologies and Their Application in Power Distribution Systems
She, X., Huang, A. Q., & Burgos, R. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2277917 · Cited by 1,164
Self-citationWu, W., Liu, Y., He, Y., Chung, H. S.-H., Liserre, M., & Blaabjerg, F. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2714143 · Cited by 397
Hannan, M. A., Ker, P. J., Lipu, M. S. H., Choi, Z. H., Rahman, M. S. A., Muttaqi, K. M., & Blaabjerg, F. (2020) · IEEE Access · doi:10.1109/access.2020.2967345 · Cited by 339
Design and Demonstration of a 3.6-kV–120-V/10-kVA Solid-State Transformer for Smart Grid Application
She, X., Yu, X., Wang, F., & Huang, A. Q. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2293471 · Cited by 324
“This might be used in applications such as wind generation systems [20].”
MethodSelf-citationHuber, J. E., & Kolar, J. W. (2014) · 2014 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2014.6954023 · Cited by 264
“Looking at lower power levels, [15] compares the cost of four different topologies suitable for a 50 kVA SST’s high-voltage side converter and [16] provides a cost breakdown of a laboratory-scale prototype of an SST for wind energy applications and, as a side note, mentions an estimated cost reduction by a factor of f…”
Background
Metadata
- Authors
- She, X., Huang, A. Q., Wang, F., & Burgos, R.
- Affiliations
- North Carolina State University (US)
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2013-10
- Volume
- 60
- Issue
- 10
- Pages
- 4512-4524
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2000794749
- Cited by
- 161
- References
- 30
- Citations by year
- 2026: 4 · 2025: 7 · 2024: 6 · 2023: 5 · 2022: 12 · 2021: 11 · 2020: 13 · 2019: 13 · 2018: 13 · 2017: 14 · 2016: 14 · 2015: 17 · 2014: 22 · 2013: 10
- FWCI
- 10.02
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Industrial Electronics (publishedVersion)
- Funders
- National Science Foundation
- North Carolina State University
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wind Turbine Control Systems
- Physical Sciences › Energy › Energy Engineering and Power Technology › Power Systems and Renewable Energy
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Keywords
- wind energy systems, solid-state transformer, reactive power compensation, active power transfer, voltage conversion, voltage fluctuation suppression, grid integration of wind power, squirrel cage induction generator, voltage and frequency regulation, cost analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wind Energy System With Integrated Functions of Active Power Transfer, Reactive Power Compensation, and Voltage Conversion. https://app.cochat.ai/papers/10.1109/tie.2012.2216245
- The paper
- She, X., Huang, A. Q., Wang, F., & Burgos, R. (2013). Wind Energy System With Integrated Functions of Active Power Transfer, Reactive Power Compensation, and Voltage Conversion. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2012.2216245
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.