The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
An Improved Control Strategy of Limiting the DC-Link Voltage Fluctuation for a Doubly Fed Induction Wind Generator
Abstract
The paper presents to develop a new control strategy of limiting the dc-link voltage fluctuation for a back-to-back pulsewidth modulation converter in a doubly fed induction generator (DFIG) for wind turbine systems. The reasons of dc-link voltage fluctuation are analyzed. An improved control strategy with the instantaneous rotor power feedback is proposed to limit the fluctuation range of the dc-link voltage. An experimental rig is set up to valid the proposed strategy, and the dynamic performances of the DFIG are compared with the traditional control method under a constant grid voltage. Furthermore, the capabilities of keeping the dc-link voltage stable are also compared in the ride-through control of DFIG during a three-phase grid fault, by using a developed 2 MW DFIG wind power system model. Both the experimental and simulation results have shown that the proposed control strategy is more effective, and the fluctuation of the dc-link voltage may be successfully limited in a small range under a constant grid voltage and a non-serious grid voltage dip.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pena, R., Clare, J. C., & Asher, G. M. (1996) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:19960288 · Cited by 2,759
Ridethrough of Wind Turbines with Doubly-Fed Induction Generator During a Voltage Dip
Morren, J., & deHaan, S. W. H. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.845526 · Cited by 873
Dynamic modeling of doubly fed induction generator wind turbines
Ekanayake, J. B., Holdsworth, L., Wu, X., & Jenkins, N. (2003) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2003.811178 · Cited by 733
Frequency support from doubly fed induction generator wind turbines
Ramtharan, G., Jenkins, N., & Ekanayake, J. B. (2007) · IET Renewable Power Generation · doi:10.1049/iet-rpg:20060019 · Cited by 530
Cited by
A Review of the State of the Art of Power Electronics for Wind Turbines
Chen, Z., Guerrero, J. M., & Blaabjerg, F. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2017082 · Cited by 1,487
Self-citationRodriguez, P., Luna, A., Candela, I., Mujal, R., Teodorescu, R., & Blaabjerg, F. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2042420 · Cited by 1,112
Overview of control systems for the operation of DFIGs in wind energy applications
Pena, R., Cardenas, R., & Asher, G. (2013) · IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2013.6699116 · Cited by 529
Huang, L., Xin, H., Wang, Z., Wu, K., Wang, H., Hu, J., & Lu, C. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2740424 · Cited by 342
Mohseni, M., & Islam, S. M. (2012) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.03.039 · Cited by 327
Metadata
- Authors
- Yao, J., Li, H., Liao, Y., & Chen, Z.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2008-05
- Volume
- 23
- Issue
- 3
- Pages
- 1205-1213
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2102434591
- Cited by
- 312
- References
- 4
- FWCI
- 22.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Improved Control Strategy of Limiting the DC-Link Voltage Fluctuation for a Doubly Fed Induction Wind Generator. https://app.cochat.ai/papers/10.1109/tpel.2008.921177
- The paper
- Yao, J., Li, H., Liao, Y., & Chen, Z. (2008). An Improved Control Strategy of Limiting the DC-Link Voltage Fluctuation for a Doubly Fed Induction Wind Generator. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2008.921177
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.