Open-Loop Control Methods for Interleaved DCM/CCM Boundary Boost PFC Converters
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Open-loop interleaving methods for PFC boost converters operating at the boundary of discontinuous-conduction mode and continuous-conduction mode with a master-slave relationship are analyzed. It is shown that the only method that results in stable operation is the synchronization of the slave converter to the turn-on instant of the master converter, where each converter operates with current-mode control. Effects of mismatched inductances, phase-shift error, switching-frequency limit, and valley switching on the quality of the input current are discussed in detail.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Steady-state analysis of an interleaved boost converter with coupled inductors
Lee, P.-W., Lee, Y.-S., Cheng, D. K. W., & Liu, X.-C. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.857959 · Cited by 498
High efficiency power factor correction using interleaving techniques
Miwa, B. A., Otten, D. M., & Schlecht, M. E. (2003) · [Proceedings] APEC '92 Seventh Annual Applied Power Electronics Conference and Exposition · doi:10.1109/apec.1992.228361 · Cited by 363 · cited 1×
“Generally, the input current ripple and, consequently, the input DM-EMI filter can be significantly reduced by interleaving two or more boost PFC converters as shown in Fig. 1 [ 6 ]–[19].”
MethodPower-factor correction with interleaved boost converters in continuous-inductor-current mode
Balogh, L., & Redl, R. (2002) · Proceedings Eighth Annual Applied Power Electronics Conference and Exposition, · doi:10.1109/apec.1993.290634 · Cited by 209
Soft Switching Circuit for Interleaved Boost Converters
Yao, G., Chen, A., & He, X. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.886649 · Cited by 180
Elmore, M. (2002) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.1996.500436 · Cited by 119 · cited 2×
“The PLL approach has been implemented by using a low-pass filter [15]-[17] or a cycleby-cycle instant averaging filter [21], and then adjusting the turn-off instant of the slave converter.”
MethodStein, C. M. D. O., Pinheiro, J. R., & Hey, H. L. (2002) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2002.805607 · Cited by 112 · cited 1×
“The slave converter with open-loop synchronization can be synchronized to the turn-on instant of the master converter [10]-[13] or to the turn-off instant of the master converter [9], [14].”
BackgroundEvaluation of input current in the critical mode boost PFC converter for distributed power systems
Zhang, J., Shao, J., Xu, P., Lee, F. C., & Jovanovic, M. M. (2002) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2001.911638 · Cited by 107 · cited 4×
“The slave converter with open-loop synchronization can be synchronized to the turn-on instant of the master converter [10]-[13] or to the turn-off instant of the master converter [9], [14].”
BackgroundMethodSelf-citationA novel closed loop interleaving strategy of multiphase critical mode boost PFC converters
Xu, X., & Huang, A. Q. (2008) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2008.4522849 · Cited by 58 · cited 3×
“Very few implementations of the interleaved DCM/CCM boundary boost PFC converters have been published in the literature [9]-[21].”
MethodChan, C. H., & Pong, M. H. (2002) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.1997.616754 · Cited by 55
Power factor correction using interleaving technique for critical mode switching converters
Ishii, T., & Mizutani, Y. (2002) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.1998.702007 · Cited by 53 · cited 1×
“The slave converter with open-loop synchronization can be synchronized to the turn-on instant of the master converter [10]-[13] or to the turn-off instant of the master converter [9], [14].”
BackgroundSwitching-Frequency Control for Regulated Discontinuous-Conduction-Mode Boost Rectifiers
Lo, Y., Lin, J., & Ou, S. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.892104 · Cited by 43
Cited by
Ultraflat Interleaved Triangular Current Mode (TCM) Single-Phase PFC Rectifier
Marxgut, C., Krismer, F., Bortis, D., & Kolar, J. W. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2258941 · Cited by 345
Su, B., Zhang, J., & Lu, Z. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2059046 · Cited by 271
Review of GaN Totem-Pole Bridgeless PFC
University of Texas at Austin, & Huang, Q. (2017) · CPSS Transactions on Power Electronics and Applications · doi:10.24295/cpsstpea.2017.00018 · Cited by 198
Interleaved Critical Current Mode Boost PFC Converter With Coupled Inductor
Yang, F., Ruan, X., Yang, Y., & Ye, Z. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2106165 · Cited by 177
“Therefore, the current-mode control [8], which makes the peak value of the inductor current be sinusoidal is more reasonable than the voltage-mode control, which only fixes the switch on-time.”
BackgroundA ZVS Interleaved Boost AC/DC Converter Used in Plug-in Electric Vehicles
Pahlevaninezhad, M., Das, P., Drobnik, J., Jain, P. K., & Bakhshai, A. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2186320 · Cited by 169
“ZVS in interleaved boost converter can be easily achieved if the current in the boost inductors is always in critical conduction mode [27], but the main problem related to such critical conduction mode boost converters is the limitation of the maximum power handling capacity of the overall converter, typically such co…”
Background
Metadata
- Authors
- Huber, L., Irving, B. T., & Jovanovic, M. M.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2008-07
- Volume
- 23
- Issue
- 4
- Pages
- 1649-1657
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2095895743
- Cited by
- 175
- References
- 11
- FWCI
- 11.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.