The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Power Flow Characterization of a Bidirectional Galvanically Isolated High-Power DC/DC Converter Over a Wide Operating Range
Abstract
This paper studies the power flow characterization of a bidirectional galvanically isolated high-power dual active bridge DC/DC converter. In experimental tests at the University of Michigan, we have observed three phenomena, which we term as internal power transfer, phase drift, and low system efficiency, that are present under certain operating conditions. These phenomena cannot be explained by conventional power transfer analysis. The authors develop a new model, based on a detailed analysis over a short time scale, that incorporates additional parameters, including the power semiconductor voltage loss and dead time. The new power flow model may be used to explain the observed phenomena and to characterize the power flow of the converter. The model may also be used to perform accurate power flow computations over a wide operating range, thereby supporting optimal hardware design, operating range selection, and power management strategy development. Experimental results are presented to illustrate the validity of the new model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new ZVS bidirectional DC-DC converter for fuel cell and battery application
Peng, F. Z., Li, H., Su, G.-J., & Lawler, J. S. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.820550 · Cited by 782
Cited by
Forouzesh, M., Siwakoti, Y. P., Gorji, S. A., Blaabjerg, F., & Lehman, B. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2652318 · Cited by 2,123
Zhao, B., Song, Q., Liu, W., & Sun, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2289913 · Cited by 1,886
Zhao, B., Yu, Q., & Sun, W. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2180928 · Cited by 932
Hou, N., & Li, Y. W. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2927930 · Cited by 553
Tan, N. M. L., Abe, T., & Akagi, H. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2108317 · Cited by 490
Metadata
- Authors
- Xie, Y., Sun, J., & Freudenberg, J. S.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2010-01
- Volume
- 25
- Issue
- 1
- Pages
- 54-66
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2170146969
- Cited by
- 250
- References
- 1
- FWCI
- 8.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Power Flow Characterization of a Bidirectional Galvanically Isolated High-Power DC/DC Converter Over a Wide Operating Range. https://app.cochat.ai/papers/10.1109/tpel.2009.2024151
- The paper
- Xie, Y., Sun, J., & Freudenberg, J. S. (2010). Power Flow Characterization of a Bidirectional Galvanically Isolated High-Power DC/DC Converter Over a Wide Operating Range. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2009.2024151
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.