Switching Control Technique of Phase-Shift-Controlled Full-Bridge Converter to Improve Efficiency Under Light-Load and Standby Conditions Without Additional Auxiliary Components
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
The main theme of this paper is to propose a switching method to reduce the loss of phase-shift-controlled full-bridge converter under light-load and standby conditions. It will be shown that the efficiency can be improved using the proposed switching control technique. The presented switching control technique controls the full-bridge converter by pulsewidth-modulated (PWM) switching mode under light-load condition and PWM switching with burst mode under standby condition. The transition point between phase-shift switching method and the proposed method is investigated and confirmed by experimental results. A field-programmable-gate-array-based digital-controlled experimental system has been set up. The specifications of the converter include: input voltage = 400 V, output voltage = 12 V, and output power = 400 W. Experimental results show that the efficiency improvement can be up to 26% under light-load condition and the standby power is less than 1 W. These results confirm the effectiveness of the proposed switching control technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design considerations for high-voltage high-power full-bridge zero-voltage-switched PWM converter
Sabate, J. A., Vlatkovic, V., Ridley, R. B., Lee, F. C., & Cho, B. H. (1990) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.1990.66420 · Cited by 1,015 · cited 1×
“The effective duty is rewritten as [20]”
Redl, R., Sokal, N. O., & Balogh, L. (1991) · IEEE Transactions on Power Electronics · doi:10.1109/63.85909 · Cited by 419
A ZVS Bidirectional DC–DC Converter With Phase-Shift Plus PWM Control Scheme
Xiao, H., & Xie, S. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.915188 · Cited by 299
High-voltage, high-power, ZVS, full-bridge PWM converter employing an active snubber
Sabate, J. A., Vlatkovic, V., Ridley, R. B., & Lee, F. C. (2002) · [Proceedings] APEC '91: Sixth Annual Applied Power Electronics Conference and Exhibition · doi:10.1109/apec.1991.146157 · Cited by 204 · cited 1×
“FULL-BRIDGE converters with phase-shift switching control [1]–[7] have been widely employed in high-power applications.”
BackgroundLee, W.-J., Kim, C.-E., Moon, G., & Han, S.-K. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.921462 · Cited by 137 · cited 3×
“As shown in [10] and [11], burst PWM mode is used under standby condition to further reduce the switching losses.”
MethodDesign of a Two-Stage AC/DC Converter with Standby Power Losses Less than 1 W
Huang, B.-T., Lee, K.-Y., & Lai, Y. (2007) · Power Conversion Conference · doi:10.1109/pccon.2007.373183 · Cited by 27 · cited 1×
“some techniques, including: 1) pulse skipping [13]; 2) burst mode [14], [15]; and 3) off-time modulation [16], [17], are applied to the power converters for reducing standby power losses.”
MethodSelf-citation
Cited by
Safayatullah, M., Elrais, M. T., Ghosh, S., Rezaii, R., & Batarseh, I. (2022) · IEEE Access · doi:10.1109/access.2022.3166935 · Cited by 615
“[215] Closed loop feedback control incorporating PWM switching and phase shift switching To increase efficiency in light load condition Vbat, Ibat Phase shift angle, duty cycle Employs PWM and phase shift switching control, PWM switching control is activated under light load condition to remove circulating loss, phase…”
BackgroundMethodHou, N., & Li, Y. W. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2927930 · Cited by 553
ZVS of Power MOSFETs Revisited
Kasper, M., Burkat, R., Deboy, F., & Kolar, J. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2574998 · Cited by 437
Rodriguez, A., Vazquez, A., Lamar, D. G., Hernando, M. M., & Sebastian, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2309853 · Cited by 352
An Automotive Onboard 3.3-kW Battery Charger for PHEV Application
Gautam, D. S., Musavi, F., Edington, M., Eberle, W., & Dunford, W. G. (2012) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2012.2210259 · Cited by 274
Metadata
- Authors
- Chen, B.-Y., & Lai, Y.-S.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2010-04
- Volume
- 25
- Issue
- 4
- Pages
- 1001-1012
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2122381462
- Cited by
- 212
- References
- 6
- FWCI
- 12.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.