The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
ZVS of Power MOSFETs Revisited
Abstract
Aiming for converters with high efficiency and high power density demands converter topologies with zero-voltage switching (ZVS) capabilities. This letter shows that in order to determine whether ZVS is provided at a given operating point, the stored charge within the mosfets has to be considered and the condition LI2≥2Qosshas to be fulfilled. In the case of incomplete soft switching, nonzero losses occur which are analytically derived and experimentally verified in this letter. Furthermore, the issue of nonideal soft-switching behavior of Si superjunction mosfets is addressed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modeling and optimization of bidirectional dual active bridge DC-DC converter topologies
Krismer, F. (2010) · Repository for Publications and Research Data (ETH Zurich) · doi:10.3929/ethz-a-006395373 · Cited by 230
Chen, B.-Y., & Lai, Y.-S. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2033069 · Cited by 212
Extreme efficiency power electronics
Kolar, J. W., Krismer, F., Lobsiger, Y., Mühlethaler, J., Nußbaumer, T., & Minibock, J. (2012) · Cited by 165
Self-citationMarxgut, C., Biela, J., & Kolar, J. W. (2010) · International Power Electronics Conference (IPEC) · doi:10.1109/ipec.2010.5542048 · Cited by 160
Self-citationMishima, T., & Nakaoka, M. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2132146 · Cited by 79
Coss related energy loss in power MOSFETs used in zero-voltage-switched applications
Fedison, J. B., Fornage, M., Harrison, M. J., & Zimmanck, D. R. (2014) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2014.6803302 · Cited by 75
COSS hysteresis in advanced superjunction MOSFETs
Fedison, J. B., & Harrison, M. J. (2016) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2016.7467880 · Cited by 64
Comparative evaluation of soft-switching concepts for bi-directional buck+boost dc-dc converters
Waffler, S., & Kolar, J. W. (2010) · International Power Electronics Conference (IPEC) · doi:10.1109/ipec.2010.5542152 · Cited by 39
Self-citation
Cited by
99% Efficient Isolated Three-Phase Matrix-Type DAB Buck–Boost PFC Rectifier
Schrittwieser, L., Leibl, M., & Kolar, J. W. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2914488 · Cited by 169
Self-citationComparison of Wide-Band-Gap Technologies for Soft-Switching Losses at High Frequencies
Jafari, A., Nikoo, M. S., Perera, N., Yildirim, H. K., Karakaya, F., Soleimanzadeh, R., & Matioli, E. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2990628 · Cited by 92
Full-ZVS modulation for all-SiC ISOP-type isolated front end (IFE) solid-state transformer
Huber, J. E., Rothmund, D., Wang, L., & Kolar, J. W. (2016) · 2016 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2016.7855128 · Cited by 31
Self-citation
Metadata
- Authors
- Kasper, M., Burkat, R., Deboy, F., & Kolar, J.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2016
- Pages
- 1-1
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2410001354
- Cited by
- 437
- References
- 8
- FWCI
- 13.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: ZVS of Power MOSFETs Revisited. https://app.cochat.ai/papers/10.1109/tpel.2016.2574998
- The paper
- Kasper, M., Burkat, R., Deboy, F., & Kolar, J. (2016). ZVS of Power MOSFETs Revisited. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2016.2574998
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.