A Transformerless Hybrid Active Filter Using a Three-Level Pulsewidth Modulation (PWM) Converter for a Medium-Voltage Motor Drive
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
This paper presents a transformerless hybrid active filter integrated into a medium-voltage motor drive for energy savings. This hybrid filter is intended for line harmonic-current mitigation of the three-phase diode rectifier used as the front end of the motor drive. It is based on direct connection of a passive filter tuned to the seventh-harmonic frequency in series with an active filter using a three-level pulsewidth modulated (PWM) converter. This paper provides a theoretical discussion on voltage-balancing control of two split dc capacitors of the active filter. The 400-V 15-kW motor drive system is designed, constructed, and tested, which can be considered as a downscaled model from a medium-voltage motor drive without regenerative braking. Experimental results verify that the hybrid filter has the capability of satisfactory harmonic filtering and stable voltage balancing in all the load conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A New Neutral-Point-Clamped PWM Inverter
Nabae, A., Takahashi, I., & Akagi, H. (1981) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1981.4503992 · Cited by 5,139 · cited 1×
“6-kV motor can be driven by a three-level NPC (neutralpoint-clamped) PWM inverter [14] with a dc-link voltage of 9 kV.”
BackgroundSelf-citationAkagi, H., Kanazawa, Y., & Nabae, A. (1984) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1984.4504460 · Cited by 3,377 · cited 1×
“4 makes the active filter yield a fundamental-frequency line-toneutral voltage that lags by 90◦ the filter current iF [27], [28].”
BackgroundSelf-citationInstantaneous Power Theory and Applications to Power Conditioning
Akagi, H., Watanabe, E. H., & Aredes, M. (2007) · Wiley eBooks · doi:10.1002/0470118938 · Cited by 2,234
Self-citationNew trends in active filters for power conditioning
Akagi, H. (1996) · IEEE Transactions on Industry Applications · doi:10.1109/28.556633 · Cited by 1,663 · cited 1×
“It has ranged from a basic research stage [3]–[6] to a practical development stage [7]–[9].”
BackgroundSelf-citationHigh‐Power Converters and ac Drives
Wu, B. (2006) · Wiley eBooks · doi:10.1002/0471773719 · Cited by 1,640
High‐Power Converters and AC Drives
Wu, B., & Narimani, M. (2017) · doi:10.1002/9781119156079 · Cited by 1,571
Akagi, H. (2005) · Proceedings of the IEEE · doi:10.1109/jproc.2005.859603 · Cited by 1,011 · cited 1×
“6-kV motor drive equipped with a hybrid active filter at the line side [13].”
BackgroundSelf-citationCelanovic, N., & Boroyevich, D. (2000) · IEEE Transactions on Power Electronics · doi:10.1109/63.838096 · Cited by 915
Ogasawara, S., & Akagi, H. (2002) · Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting · doi:10.1109/ias.1993.299015 · Cited by 296 · cited 1×
“This allows one to assume the duty factor D as a function of the active filter voltage vAF as follows [19]:”
MethodSelf-citationNatural balancing of three-level neutral-point-clamped PWM inverters
du Toit Mouton, H. (2002) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2002.803205 · Cited by 215
Cited by
Classification, Terminology, and Application of the Modular Multilevel Cascade Converter (MMCC)
Akagi, H. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2143431 · Cited by 1,172
Self-citationMultilevel Converters: Fundamental Circuits and Systems
Akagi, H. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2682105 · Cited by 513
“The required power ratings of the passive and active filters are 25% and 6%, respectively, of that of the diode rectifier [23].”
BackgroundSelf-citationHagiwara, M., Hasegawa, I., & Akagi, H. (2013) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2013.2256331 · Cited by 291
Self-citationA Novel Nine-Level Quadruple Boost Inverter With Inductive-Load Ability
Liu, J., Lin, W., Wu, J., & Zeng, J. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2873188 · Cited by 168
Zhou, D., Yang, S., & Tang, Y. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2796584 · Cited by 143
Zhou, D., Yang, S., & Tang, Y. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2863181 · Cited by 88
“systems [6], medium-voltage motor drives [7], [8], and energy storage systems [9], thanks to their advanced benefits of modu-”
Background
Metadata
- Authors
- Akagi, H., & Kondo, R.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2010-06
- Volume
- 25
- Issue
- 6
- Pages
- 1365-1374
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2141466927
- Cited by
- 159
- References
- 18
- FWCI
- 11.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.