Abstract
This paper focuses on fault-tolerant control for a battery-energy-storage system based on a multilevel cascade pulsewidth-modulation (PWM) converter with star configuration. During the occurrence of a single-converter-cell or single-battery-unit fault, the fault-tolerant control enables continuous operation and maintains state-of-charge balancing of the remaining healthy battery units. This enhances both system reliability and availability. A 200-V, 10-kW, 3.6-kW·h laboratory system combining a three-phase cascade PWM converter with nine nickel-metal-hydride battery units is designed, constructed, and tested to verify the validity and effectiveness of the proposed fault-tolerant control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Modular Multilevel Converters for Transportation Electrification: Challenges and Opportunities
Ronanki, D., & Williamson, S. S. (2018) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2018.2792330 · Cited by 345
Kim, J., Shin, J., Chun, C., & Cho, B. H. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2158553 · Cited by 278
A Hybrid Cascaded Multilevel Converter for Battery Energy Management Applied in Electric Vehicles
Zheng, Z., Wang, K., Xu, L., & Li, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2279185 · Cited by 263
Power converter interfaces for electrochemical energy storage systems – A review
Fernão Pires, V., Romero-Cadaval, E., Vinnikov, D., Roasto, I., & Martins, J. F. (2014) · Energy Conversion and Management · doi:10.1016/j.enconman.2014.05.003 · Cited by 254
Li, J., Huang, A. Q., Liang, Z., & Bhattacharya, S. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2143430 · Cited by 211
Metadata
- Authors
- Maharjan, L., Yamagishi, T., Akagi, H., & Asakura, J.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2010-09
- Volume
- 25
- Issue
- 9
- Pages
- 2386-2396
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2112907007
- Cited by
- 242
- References
- 0
- FWCI
- 10.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fault-Tolerant Operation of a Battery-Energy-Storage System Based on a Multilevel Cascade PWM Converter With Star Configuration. https://app.cochat.ai/papers/10.1109/tpel.2010.2047407
- The paper
- Maharjan, L., Yamagishi, T., Akagi, H., & Asakura, J. (2010). Fault-Tolerant Operation of a Battery-Energy-Storage System Based on a Multilevel Cascade PWM Converter With Star Configuration. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2010.2047407
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.