Abstract
Permanent magnet (PM) machines provide high efficiency, compact size, robustness, lightweight, and low noise. These features qualify them as the best suitable machine for medical applications. The system presented in this paper is a self-contained, small size, and reliable device that can continuously provide power. The core of the system is a linear generator that consists of two layers of PMs and one layer of coils. It generates power from multidirectional body movements. The movement of the device causes the coil layer to move. The relative movement of the coils versus PMs, on two sides, creates a varying flux in the windings. This change in flux produces voltage in the winding and can be converted into electrical power if a load is connected. The best place to implement this device to produce continuous power is on a muscle inside the body that is linked to the respiratory system. Design, simulation, implementation, and testing of the generator are presented in this paper. The testing results reveal that the generator can produce up to 1 mW of power in the body.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Power Approaches for Implantable Medical Devices
Amar, A., Kouki, A., & Cao, H. (2015) · Sensors · doi:10.3390/s151128889 · Cited by 432
Roy, S., Azad, A. N. M. W., Baidya, S., Alam, M. K., & Khan, F. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3164890 · Cited by 255
Challenges for successful implantation of biofuel cells
Zebda, A., Alcaraz, J.-P., Vadgama, P., Shleev, S., Minteer, S. D., Boucher, F., Cinquin, P., & Martin, D. K. (2018) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2018.05.011 · Cited by 224
A review of acoustic power transfer for bio-medical implants
Basaeri, H., Christensen, D. B., & Roundy, S. (2016) · Smart Materials and Structures · doi:10.1088/0964-1726/25/12/123001 · Cited by 202
Powering implantable and ingestible electronics
Yang, S., Sencadas, V., You, S. S., Jia, N. Z., Srinivasan, S. S., Huang, H., Ahmed, A. E., Liang, J. Y., & Traverso, G. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202009289 · Cited by 183
Metadata
- Authors
- Nasiri, A., Zabalawi, S. A., & Jeutter, D. C.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2011-01
- Volume
- 26
- Issue
- 1
- Pages
- 192-199
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2018176627
- Cited by
- 48
- References
- 0
- FWCI
- 3.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Linear Permanent Magnet Generator for Powering Implanted Electronic Devices. https://app.cochat.ai/papers/10.1109/tpel.2010.2055891
- The paper
- Nasiri, A., Zabalawi, S. A., & Jeutter, D. C. (2011). A Linear Permanent Magnet Generator for Powering Implanted Electronic Devices. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2010.2055891
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.