This paper proposes a hardware in-the-loop simulation (HILS) system as a new method to develop and test control algorithms and operation strategies for a microgrid. The HILS system is composed of a real-time digital simulator (RTDS) for real-time simulation of the microgrid, a prototype microgrid management system (MMS) under test, and a communication emulator for interface between the prototype MMS and the RTDS. The prototype MMS is designed to operate microsources of microgrid and to control power flow at the point of common coupling (PCC) in the grid-connected mode, and voltages and frequency in the islanded mode of the microgrid. The MMS is tested in the grid-connected mode and in the islanded mode, respectively, to show the validation of the proposed HILS system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modeling, Analysis and Testing of Autonomous Operation of an Inverter-Based Microgrid
Pogaku, N., Prodanovic, M., & Green, T. C. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.890003 · Cited by 3,018 · cited 1×
“Field tests have been performed for frequency and voltage control algorithms, and for utility interconnection devices [16]–[18].”
BackgroundHatziargyriou, N., Asano, H., Iravani, R., & Marnay, C. (2007) · IEEE Power and Energy Magazine · doi:10.1109/mpae.2007.376583 · Cited by 2,519
A Voltage and Frequency Droop Control Method for Parallel Inverters
De Brabandere, K., Bolsens, B., Van den Keybus, J., Woyte, A., Driesen, J., & Belmans, R. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.900456 · Cited by 1,865
Katiraei, F., Iravani, R., Hatziargyriou, N., & Dimeas, A. (2008) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2008.918702 · Cited by 1,591
Li, Y. W., & Kao, C.-N. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2022828 · Cited by 1,127
Guerrero, J. M., Matas, J., Garcia de Vicuna, L., Castilla, M., & Miret, J. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.892621 · Cited by 1,085
Centralized Control for Optimizing Microgrids Operation
Tsikalakis, A. G., & Hatziargyriou, N. D. (2008) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2007.914686 · Cited by 899
Energy Management in Autonomous Microgrid Using Stability-Constrained Droop Control of Inverters
Barklund, E., Pogaku, N., Prodanovic, M., Hernandez-Aramburo, C., & Green, T. C. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2001910 · Cited by 733 · cited 1×
“A distributed intelligent energy management system was implemented to optimize operating costs [5], [ 6 ].”
MethodDesign, Analysis, and Real-Time Testing of a Controller for Multibus Microgrid System
Li, Y., Vilathgamuwa, D. M., & Loh, P. C. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833456 · Cited by 723
Kroposki, B., Lasseter, R., Ise, T., Morozumi, S., Papathanassiou, S., & Hatziargyriou, N. (2008) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2008.918718 · Cited by 641 · cited 1×
“strategies for microgrid [20].”
Cited by
Guerrero, J. M., Chandorkar, M., Lee, T.-L., & Loh, P. C. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2194969 · Cited by 1,976
Guerrero, J. M., Loh, P. C., Lee, T.-L., & Chandorkar, M. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2196889 · Cited by 965
Battery Management System: An Overview of Its Application in the Smart Grid and Electric Vehicles
Rahimi-Eichi, H., Ojha, U., Baronti, F., & Chow, M.-Y. (2013) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2013.2250351 · Cited by 960
Zhao, B., Yu, Q., & Sun, W. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2180928 · Cited by 932
“Generally, microgrids can operate in grid-connected mode and islanded mode [6], [7].”
BackgroundResearch on voltage and power balance control for cascaded modular solid-state transformer
Shi, J., Gou, W., Yuan, H., Zhao, T., & Huang, A. Q. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2106803 · Cited by 362
Marinescu, A., Taylor, A., Clarke, S., Serban, I., & Marinescu, C. (2019) · International Journal of Energy Research · doi:10.1002/er.4559 · Cited by 9
“27 In this, the stability, operation and fault tolerance of the system can be more thoroughly evaluated.”
Background
Metadata
- Authors
- Jeon, J.-H., Kim, J.-Y., Kim, H.-M., Kim, S.-K., Cho, C., Kim, J.-M., Ahn, J.-B., & Nam, K.-Y.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2010-12
- Volume
- 25
- Issue
- 12
- Pages
- 2919-2929
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2140680794
- Cited by
- 181
- References
- 18
- FWCI
- 18.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.