The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Quantitative Evaluation of DC Microgrids Availability: Effects of System Architecture and Converter Topology Design Choices
Abstract
This paper presents a quantitative method to evaluate dc microgrids availability by identifying and calculating minimum cut sets occurrence probability for different microgrid architectures and converter topologies. Hence, it provides planners with an essential tool to evaluate downtime costs and decide technology deployments based on quantitative risk assessments by allowing to compare the effect that converter topologies and microgrid architecture choices have on availability. Conventional architectures with single-input converters and alternative configurations with multiple-input converters (MICs) are considered. Calculations yield that all microgrid configurations except those utilizing center converters achieve similar availability of 6-nines. Three converter topologies are used as representatives of many other circuits. These three benchmark circuits are the boost, the isolated SEPIC (ISEPIC), and the current-source half-bridge. Marginal availability differences are observed for different circuit topology choices, although architectures with MICs are more sensitive to this choice. MICs and, in particular, the ISEPIC, are identified as good compromise options for dc microgrids source interfaces. The analysis also models availability influence of local energy storage, both in batteries and generators' fuel. These models provide a quantitative way of comparing dc microgrids with conventional backup energy systems. Calculations based on widely accepted data in industry supports the analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reliability Evaluation of Power Systems
Billinton, R., & Allan, R. N. (1984) · Springer eBooks · doi:10.1007/978-1-4615-7731-7 · Cited by 3,350
Power electronics as efficient interface in dispersed power generation systems
Blaabjerg, F., Chen, Z., & Kjaer, S. B. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833453 · Cited by 2,588
Mohamed, Y., & El-Saadany, E. F. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2005100 · Cited by 1,230
Li, Y. W., & Kao, C.-N. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2022828 · Cited by 1,127
Energy Management in Autonomous Microgrid Using Stability-Constrained Droop Control of Inverters
Barklund, E., Pogaku, N., Prodanovic, M., Hernandez-Aramburo, C., & Green, T. C. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2001910 · Cited by 733
Fuel Consumption Minimization of a Microgrid
Hernandez-Aramburo, C. A., Green, T. C., & Mugniot, N. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.847277 · Cited by 526
A multiple-input DC-DC converter topology
Dobbs, B. G., & Chapman, P. L. (2003) · IEEE Power Electronics Letters · doi:10.1109/lpel.2003.813481 · Cited by 511
Family of multiport bidirectional DC–DC converters
Tao, H., Kotsopoulos, A., Duarte, J. L., & Hendrix, M. A. M. (2006) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:20050362 · Cited by 488
Distributed Generation Interface to the CERTS Microgrid
Nikkhajoei, H., & Lasseter, R. H. (2009) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2009.2021040 · Cited by 409
DC microgrid based distribution power generation system
Ito, Y., Yang, Z., & Akagi, H. (2004) · International Power Electronics and Motion Control Conference · Cited by 383
Cited by
DC Microgrids—Part II: A Review of Power Architectures, Applications, and Standardization Issues
Dragicevic, T., Lu, X., Vasquez, J. C., & Guerrero, J. M. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2464277 · Cited by 1,451
AC-microgrids versus DC-microgrids with distributed energy resources: A review
Justo, J. J., Mwasilu, F., Lee, J., & Jung, J.-W. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.03.067 · Cited by 1,245
Anand, S., Fernandes, B. G., & Guerrero, J. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2215055 · Cited by 920
DC microgrids and distribution systems: An overview
Elsayed, A. T., Mohamed, A. A., & Mohammed, O. A. (2015) · Electric Power Systems Research · doi:10.1016/j.epsr.2014.10.017 · Cited by 590
Distribution Voltage Control for DC Microgrids Using Fuzzy Control and Gain-Scheduling Technique
Kakigano, H., Miura, Y., & Ise, T. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2217353 · Cited by 391
Metadata
- Authors
- Kwasinski, A.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2011-03
- Volume
- 26
- Issue
- 3
- Pages
- 835-851
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2105499934
- Cited by
- 288
- References
- 25
- FWCI
- 39.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative Evaluation of DC Microgrids Availability: Effects of System Architecture and Converter Topology Design Choices. https://app.cochat.ai/papers/10.1109/tpel.2010.2102774
- The paper
- Kwasinski, A. (2011). Quantitative Evaluation of DC Microgrids Availability: Effects of System Architecture and Converter Topology Design Choices. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2010.2102774
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.