Distributed Generation Interface to the CERTS Microgrid
Abstract
This paper focuses on the energy storage system and the power electronic interface included in microsources of the CERTS microgrid. CERTS stands for the Consortium for Electric Reliability Technology Solutions. The consortium was formed in 1999 to research, develop, and disseminate new methods, tools, and technologies to protect and enhance the reliability of the U.S. electric power system and efficiency of competitive electricity markets. To provide the plug-and-play feature and the power quality requirements of the CERTS microgrid, all microsources regardless of their prime mover type must have a unified dynamic performance. This necessitates attaching an energy storage module to some or all of the microsources. The storage module is attached to the prime mover through a power electronic interface that couples the microsource to the microgrid. Details of the energy storage module, the power electronic interface and the corresponding controls are described. Performance of an example microsource, which includes a synchronous generator, a storage module and an electronic interface, is studied. Dynamic performance of the example microsource when operating in the CERTS microgrid is evaluated based on digital time-domain simulations in the EMTP-RV software environment. Effectiveness of the storage module, the electronic interface and the corresponding controls in enhancing the microsource performance is verified.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Olivares, D. E., Mehrizi-Sani, A., Etemadi, A. H., Canizares, C. A., Iravani, R., Kazerani, M., Hajimiragha, A. H., Gomis-Bellmunt, O., Saeedifard, M., Palma-Behnke, R., et al. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2295514 · Cited by 3,137
Hierarchical Structure of Microgrids Control System
Bidram, A., & Davoudi, A. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2197425 · Cited by 1,515
Liu, J., Miura, Y., & Ise, T. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2465852 · Cited by 1,243
Control and Operation of a DC Microgrid With Variable Generation and Energy Storage
Xu, L., & Chen, D. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2158456 · Cited by 567
Basak, P., Chowdhury, S., Halder nee Dey, S., & Chowdhury, S. P. (2012) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.05.043 · Cited by 508
Metadata
- Authors
- Nikkhajoei, H., & Lasseter, R. H.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2009-07
- Volume
- 24
- Issue
- 3
- Pages
- 1598-1608
- ISSN
- 0885-8977 (ISSN-L)
- OpenAlex
- W2103943551
- Cited by
- 409
- References
- 0
- FWCI
- 49.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Distributed Generation Interface to the CERTS Microgrid. https://app.cochat.ai/papers/10.1109/tpwrd.2009.2021040
- The paper
- Nikkhajoei, H., & Lasseter, R. H. (2009). Distributed Generation Interface to the CERTS Microgrid. IEEE Transactions on Power Delivery. https://doi.org/10.1109/tpwrd.2009.2021040
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.