Control and Design of a Modular Multilevel Cascade BTB System Using Bidirectional Isolated DC/DC Converters
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper discusses the control and design of the 6.6-kV back-to-back (BTB) system combining bidirectional isolated dc/dc converters and modular multilevel cascade pulsewidth modulation (PWM) converters. The system consists of multiple converter cells connected in cascade per phase at both front ends. Each converter cell consists of a bidirectional isolated medium-frequency dc/dc converter and two voltage-source H-bridge (single-phase full-bridge) PWM converters. Extremely low-voltage steps bring a significant reduction in harmonics and electromagnetic interference emissions to the BTB system. This paper designs, constructs, and tests a single-phase downscaled BTB system rated at 120 V and 3.3 kW to verify the viability and effectiveness, leading to the actual system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An actively cooled high power, high frequency transformer with high insulation capability
Heinemann, L. (2003) · APEC. Seventeenth Annual IEEE Applied Power Electronics Conference and Exposition (Cat. No.02CH37335) · doi:10.1109/apec.2002.989270 · Cited by 135
Cited by
Zhao, B., Song, Q., Liu, W., & Sun, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2289913 · Cited by 1,886
Minimum-Current-Stress Scheme of Dual Active Bridge DC-DC Converter With Unified-phase-shift Control
Hou, N., Song, W., & wu, M. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2521410 · Cited by 369
Zhao, B., Song, Q., & Liu, W. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2210563 · Cited by 325
Design and Demonstration of a 3.6-kV–120-V/10-kVA Solid-State Transformer for Smart Grid Application
She, X., Yu, X., Wang, F., & Huang, A. Q. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2293471 · Cited by 324
“Different controllers have been proposed previously while either the parameter mismatch is not considered [13], or SST functions are affected [42], or additional”
BackgroundAn Overview of Soft Open Points in Electricity Distribution Networks
Jiang, X., Zhou, Y., Ming, W., Yang, P., & Wu, J. (2022) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2022.3148599 · Cited by 278
Metadata
- Authors
- Akagi, H., & Kitada, R.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2011-09
- Volume
- 26
- Issue
- 9
- Pages
- 2457-2464
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2167132394
- Cited by
- 147
- References
- 1
- FWCI
- 13.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Control and Design of a Modular Multilevel Cascade BTB System Using Bidirectional Isolated DC/DC Converters. https://app.cochat.ai/papers/10.1109/tpel.2011.2107752
- The paper
- Akagi, H., & Kitada, R. (2011). Control and Design of a Modular Multilevel Cascade BTB System Using Bidirectional Isolated DC/DC Converters. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2011.2107752
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.