Operation and Control of a Hybrid Seven-Level Converter
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
This paper introduces a novel hybrid seven-level converter that is based on the upgrade of the five-level active neutral-point-clamped converter concept and is suitable for high-power applications. The paper provides a comprehensive analysis for the operation of the converter. Based on the analysis, a space vector modulation (SVM)-based switching strategy that takes advantage of redundant switching vectors of the SVM strategy to counteract the voltage drift phenomenon of the proposed converter is proposed. The limit to the range of operation of the seven-level converter based on the proposed SVM strategy is also presented. It is shown that the ability to stabilize the dc-link capacitor voltages and the per-phase flying capacitors is a function of the converter operating indices, i.e., the load power factor and modulation index. The salient feature of the proposed SVM-based control strategy is that it enables proper operation of the converter with no requirements for additional controls or auxiliary power circuitry, within the specified range of operation. Performance of a converter under various operating conditions, based on the proposed SVM strategy, in the MATLAB/Simulink environment, is evaluated and experimentally demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multilevel inverters: a survey of topologies, controls, and applications
Rodriguez, J., Lai, J.-S., & Peng, F. Z. (2002) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2002.801052 · Cited by 6,715 · cited 2×
“MULTILEVEL converters have attracted significant interest for high power/voltage applications since, as compared with two-level converters, they 1) provide higher power quality at the ac side; 2) can operate at higher ac voltage levels and minimize or even eliminate the interface transformer; and 3) reduce switching l…”
BackgroundRecent Advances and Industrial Applications of Multilevel Converters
Kouro, S., Malinowski, M., Gopakumar, K., Pou, J., Franquelo, L. G., Wu, B., Rodriguez, J., Pérez, M. A., & Leon, J. I. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2049719 · Cited by 3,872
Multilevel Voltage-Source-Converter Topologies for Industrial Medium-Voltage Drives
Rodriguez, J., Bernet, S., Wu, B., Pontt, J. O., & Kouro, S. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.907044 · Cited by 2,385 · cited 2×
“MULTILEVEL converters have attracted significant interest for high power/voltage applications since, as compared with two-level converters, they 1) provide higher power quality at the ac side; 2) can operate at higher ac voltage levels and minimize or even eliminate the interface transformer; and 3) reduce switching l…”
BackgroundA Survey on Neutral-Point-Clamped Inverters
Rodriguez, J., Bernet, S., Steimer, P. K., & Lizama, I. E. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2032430 · Cited by 1,813 · cited 1×
“Conceptually, an ANPC does not have the drawbacks of the FCC and DCC converters [14]–[16].”
BackgroundSelf-citationHybrid multilevel power conversion system: a competitive solution for high-power applications
Manjrekar, M. D., Steimer, P. K., & Lipo, T. A. (2000) · IEEE Transactions on Industry Applications · doi:10.1109/28.845059 · Cited by 739
Self-citationA fast space-vector modulation algorithm for multilevel three-phase converters
Celanovic, N., & Boroyevich, D. (2001) · IEEE Transactions on Industry Applications · doi:10.1109/28.913731 · Cited by 703
A fast space vector modulation algorithm for multilevel three-phase converters
Celanovic, N., & Boroyevich, D. (2003) · Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370) · doi:10.1109/ias.1999.801652 · Cited by 627
Control of a Hybrid Asymmetric Multilevel Inverter for Competitive Medium-Voltage Industrial Drives
Veenstra, M., & Rufer, A. C. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.844382 · Cited by 334
Diode-clamped multilevel converters: a practicable way to balance DC-link voltages
Marchesoni, M., & Tenca, P. (2002) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2002.801237 · Cited by 322 · cited 2×
“It is proven that with an elaborate control strategy, the capacitor voltages of an n-level (n > 3) DCC can be maintained balanced within a viable range of operation, in terms of the modulation index and ac-side power factor [4]–[6].”
BackgroundActive Neutral-Point-Clamped Multilevel Converters
Barbosa, P., Steimer, P., Meysenc, L., Winkelnkemper, M., Steinke, J., & Celanovic, N. (2006) · IEEE 36th Conference on Power Electronics Specialists, 2005. · doi:10.1109/pesc.2005.1581952 · Cited by 306
Self-citation
Cited by
A Survey of Low Switching Frequency Modulation Techniques for Medium-Voltage Multilevel Converters
Edpuganti, A., & Rathore, A. K. (2015) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2015.2437351 · Cited by 209
A New Multilevel Inverter Topology With Self-Balancing Level Doubling Network
Chattopadhyay, S. K., & Chakraborty, C. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2290751 · Cited by 184
“All of these works overcome the voltage balancing problem of the floating capacitor with considerable effort, necessitating either some algorithm [11]–[17], [26], [27], [29], [31] or external voltage balancing network [28].”
BackgroundA review on symmetric, asymmetric, hybrid and single DC sources based multilevel inverter topologies
Venkataramanaiah, J., Suresh, Y., & Panda, A. K. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.03.066 · Cited by 182
Narimani, M., Wu, B., Yaramasu, V., & Reza Zargari, N. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2396033 · Cited by 164
“The main features of these configurations, as compared with the two-level VSC, are their capabilities to reduce: a) harmonic distortion of the ac-side waveforms, b) dv/dt switching stresses, c) switching losses, and d) minimize or even eliminate the interface transformer [1]–[5].”
BackgroundA new nested neutral point clamped (NNPC) converter for medium-voltage (MV) power conversion
Narimani, M., Wu, B., Cheng, G., & Zargari, N. (2014) · 2014 IEEE Applied Power Electronics Conference and Exposition - APEC 2014 · doi:10.1109/apec.2014.6803635 · Cited by 24
“The reference vector is synthesized by the three adjacent switching vectors [5], [16] and the can be describes as;”
Background
Metadata
- Authors
- Saeedifard, M., Barbosa, P. M., & Steimer, P. K.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2012-02
- Volume
- 27
- Issue
- 2
- Pages
- 652-660
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W1982553445
- Cited by
- 167
- References
- 16
- FWCI
- 6.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Operation and Control of a Hybrid Seven-Level Converter. https://app.cochat.ai/papers/10.1109/tpel.2011.2158114
- The paper
- Saeedifard, M., Barbosa, P. M., & Steimer, P. K. (2012). Operation and Control of a Hybrid Seven-Level Converter. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2011.2158114
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.