The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Investigation and Active Damping of Multiple Resonances in a Parallel-Inverter-Based Microgrid
Abstract
This paper addresses the resonance problem in a parallel-inverter-based grid-interactive microgrid. Unlike the single grid-connected inverter system where the resonance frequency is mainly fixed by the inverter output LCL filter parameters, the parallel-inverter-based grid-interactive microgrid system presents a more challenging picture where inverter interactions will excite complex resonances at various frequencies. As a result, line currents of inverters can be severely distorted even when the control schemes and filter circuits are properly designed based on the single-inverter model. This paper first develops a microgrid model using discrete time-domain closed-loop Norton's equivalent circuit. Multiple resonances can then be evaluated with the developed model. To improve the microgrid power quality, this paper also designs a virtual-harmonic-resistance-based active damping method. The proposed damping method can be seamlessly incorporated into the conventional deadbeat control scheme through the direct control reference modification. Therefore, the active damping method is able to address both the transient and steady-state resonances within the deadbeat current control bandwidth. Simulation and experimental results are provided to validate the correctness of the developed resonance modeling and active damping methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
Blaabjerg, F., Teodorescu, R., Liserre, M., & Timbus, A. V. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.881997 · Cited by 5,220
Power-Electronic Systems for the Grid Integration of Renewable Energy Sources: A Survey
Carrasco, J. M., Franquelo, L. G., Bialasiewicz, J. T., Galvan, E., PortilloGuisado, R. C., Prats, M. A. M., Leon, J. I., & Moreno-Alfonso, N. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.878356 · Cited by 4,018
Output Impedance Design of Parallel-Connected UPS Inverters With Wireless Load-Sharing Control
Guerrero, J. M., GarciadeVicuna, L., Matas, J., Castilla, M., & Miret, J. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.851634 · Cited by 1,221
Liserre, M., Teodorescu, R., & Blaabjerg, F. (2006) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2005.861185 · Cited by 1,101
Guerrero, J. M., GarciadeVicuna, L., Matas, J., Castilla, M., & Miret, J. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833451 · Cited by 1,039
Grid current regulation of a three-phase voltage source inverter with an LCL input filter
Twining, E., & Holmes, D. G. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.810838 · Cited by 901
Enslin, J. H. R., & Heskes, P. J. M. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.836615 · Cited by 824
Agorreta, J. L., Borrega, M., López, J., & Marroyo, L. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2095429 · Cited by 596
Control and Resonance Damping of Voltage-Source and Current-Source Converters With $LC$ Filters
Li, Y. W. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2009562 · Cited by 372
Self-citationA Cooperative Imbalance Compensation Method for Distributed-Generation Interface Converters
Cheng, P.-T., Chen, C.-A., Lee, T.-L., & Kuo, S.-Y. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2013601 · Cited by 253
Zeng, Q., & Chang, L. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.907674 · Cited by 231
Active Damping Control of a High-Power PWM Current-Source Rectifier for Line-Current THD Reduction
Wiseman, J. C., & Wu, B. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.843939 · Cited by 170
Cited by
Definition and Classification of Power System Stability – Revisited & Extended
Hatziargyriou, N., Milanovic, J., Rahmann, C., Ajjarapu, V., Canizares, C., Erlich, I., Hill, D., Hiskens, I., Kamwa, I., Pal, B., et al. (2021) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2020.3041774 · Cited by 1,244
Microgrid Stability Definitions, Analysis, and Examples
Farrokhabadi, M., Canizares, C. A., Simpson-Porco, J. W., Nasr, E., Fan, L., Mendoza-Araya, P. A., Tonkoski, R., Tamrakar, U., Hatziargyriou, N., Lagos, D., et al. (2020) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2019.2925703 · Cited by 752
An Active Damper for Stabilizing Power-Electronics-Based AC Systems
Wang, X., Blaabjerg, F., Liserre, M., Chen, Z., He, J., & Li, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2278716 · Cited by 367
Self-citationSaber, C., Labrousse, D., Revol, B., & Gascher, A. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2500958 · Cited by 73
Metadata
- Authors
- He, J., Li, Y. W., Bosnjak, D., & Harris, B.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2013-01
- Volume
- 28
- Issue
- 1
- Pages
- 234-246
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2129669526
- Cited by
- 466
- References
- 12
- FWCI
- 45.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.