Interleaved High Step-Up ZVT Converter With Built-In Transformer Voltage Doubler Cell for Distributed PV Generation System
Abstract
In this paper, the concept of built-in transformer voltage doubler cell is derived to generate an improved interleaved high step-up converter for distributed photovoltaic generation applications. The proposed built-in transformer voltage doubler cell is composed of three transformer windings, two voltage doubler diodes, and two voltage doubler capacitors. The voltage doubler capacitors are charged and discharged alternatively to double the voltage gain. The switch duty cycle and the transformer turns ratio can be employed as two controllable freedoms to lift the voltage ratio flexibly. The power device voltage stress can also be reduced to improve the circuit performance. Furthermore, the active clamp scheme is adopted to recycle the leakage energy, absorb the switch turn-off voltage spikes, and achieve zero-voltage switching (ZVS) operation for all active switches. Meanwhile, the diode reverse-recovery problem is alleviated by the leakage inductance of the built-in transformer. All these factors benefit the circuit performance improvements in the high step-up and large current applications. Finally, a 1-kW prototype with 40–380 V conversion is built and tested to demonstrate the effectiveness of the proposed converter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Review of Nonisolated High-Step-Up DC/DC Converters in Photovoltaic Grid-Connected Applications
Li, W., & He, X. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2049715 · Cited by 1,423
Self-citation
Cited by
Forouzesh, M., Siwakoti, Y. P., Gorji, S. A., Blaabjerg, F., & Lehman, B. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2652318 · Cited by 2,123
Overview of High-Step-Up Coupled-Inductor Boost Converters
Liu, H., Hu, H., Wu, H., Xing, Y., & Batarseh, I. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2016.2532930 · Cited by 432
Forouzesh, M., Shen, Y., Yari, K., Siwakoti, Y. P., & Blaabjerg, F. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2746750 · Cited by 431
Novel High Step-Up DC–DC Converter With Coupled-Inductor and Switched-Capacitor Techniques
Hsieh, Y.-P., Chen, J.-F., Liang, T.-J., & Yang, L.-S. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2151828 · Cited by 326
Metadata
- Authors
- Li, W., Xiang, X., Li, C., Li, W., & He, X.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2013-01
- Volume
- 28
- Issue
- 1
- Pages
- 300-313
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2010518284
- Cited by
- 170
- References
- 1
- FWCI
- 7.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.