The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Design and Implementation of Energy Management System With Fuzzy Control for DC Microgrid Systems
Abstract
This paper presents the design and implementation of an energy management system (EMS) with fuzzy control for a dc microgrid system. Modeling, analysis, and control of distributed power sources and energy storage devices with MATLAB/Simulink are proposed, and the integrated monitoring EMS is implemented with LabVIEW. To improve the life cycle of the battery, fuzzy control manages the desired state of charge. The RS-485/ZigBee network has been designed to control the operating mode and to monitor the values of all subsystems in the dc microgrid system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Towards a 99% Efficient Three-Phase Buck-Type PFC Rectifier for 400-V DC Distribution Systems
Stupar, A., Friedli, T., Minibock, J., & Kolar, J. W. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2166406 · Cited by 217
Mathematical Model and Characterization of the Transient Behavior of a PEM Fuel Cell
Friede, W., Rael, S., & Davat, B. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833449 · Cited by 177
Adaptive Fuzzy-Neural-Network Design for Voltage Tracking Control of a DC–DC Boost Converter
Wai, R.-J., & Shih, L.-C. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2169685 · Cited by 165
Power control of DC microgrid using DC bus signaling
Zhang, L., Wu, T., Xing, Y., Sun, K., & Gurrero, J. M. (2011) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2011.5744859 · Cited by 116
DSP-Based Probabilistic Fuzzy Neural Network Control for Li-Ion Battery Charger
Lin, F., Huang, M., Yeh, P.-Y., Tsai, H.-C., & Kuan, C. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2187073 · Cited by 101
EV/HEV Li-ion battery modelling and State-of-Function determination
Gould, C., Wang, J., Stone, D. A., & Foster, M. P. (2012) · International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM) · doi:10.1109/speedam.2012.6264616 · Cited by 23
Towards a 99% efficient three-phase buck-type PFC rectifier for 400 V DC distribution systems
Stupar, A., Friedli, T., Minibock, J., Schweizer, M., & Kolar, J. W. (2011) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2011.5744644 · Cited by 22
Cited by
Lu, X., Guerrero, J. M., Sun, K., & Vasquez, J. C. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2266419 · Cited by 1,049
Distributed Adaptive Droop Control for DC Distribution Systems
Nasirian, V., Davoudi, A., Lewis, F. L., & Guerrero, J. M. (2014) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2014.2350458 · Cited by 477
Diaz, N. L., Dragicevic, T., Vasquez, J. C., & Guerrero, J. M. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2014.2341740 · Cited by 309
Choudhury, S. (2022) · Journal of Energy Storage · doi:10.1016/j.est.2022.103966 · Cited by 283
Analysis of dual-carrier modulator for bidirectional noninverting buck–boost converter
Aharon, I., Kuperman, A., & Shmilovitz, D. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2315993 · Cited by 97
Metadata
- Authors
- Chen, Y.-K., Wu, Y.-C., Song, C.-C., & Chen, Y.-S.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2013-04
- Volume
- 28
- Issue
- 4
- Pages
- 1563-1570
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2167134908
- Cited by
- 384
- References
- 7
- FWCI
- 28.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design and Implementation of Energy Management System With Fuzzy Control for DC Microgrid Systems. https://app.cochat.ai/papers/10.1109/tpel.2012.2210446
- The paper
- Chen, Y.-K., Wu, Y.-C., Song, C.-C., & Chen, Y.-S. (2013). Design and Implementation of Energy Management System With Fuzzy Control for DC Microgrid Systems. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2012.2210446
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.