The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Towards a 99% Efficient Three-Phase Buck-Type PFC Rectifier for 400-V DC Distribution Systems
Abstract
In telecom applications, the vision for a total power conversion efficiency from the mains to the output of point-of-load (PoL) converters of 95% demands optimization of every conversion step, i.e., the power factor correction (PFC) rectifier front-end should show an outstanding efficiency in the range of 99%. For recently discussed 400-V dc distribution bus voltages, a buck-type PFC rectifier is a logical solution. In this paper, an efficiency-optimized, 98.8% efficient, 5-kW three-phase buck-type PFC rectifier with 400-V output is presented. Methods for calculating losses of all components are described and are used to optimize the converter design for efficiency at full load. Special attention is paid to semiconductor losses, which are shown to be dominant, with the parasitic device capacitance losses being a significant component. The calculation of these parasitic capacitance losses is treated in detail, and the charge-balance approach used is verified. A prototype of the proposed rectifier is constructed which verifies the accuracy of the models used for loss calculation and optimization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calculation of losses in ferro- and ferrimagnetic materials based on the modified Steinmetz equation
Reinert, J., Brockmeyer, A., & De Doncker, R. W. A. A. (2001) · IEEE Transactions on Industry Applications · doi:10.1109/28.936396 · Cited by 704
Cited by
Zhao, B., Song, Q., Liu, W., & Sun, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2289913 · Cited by 1,886
Extreme Fast Charging of Electric Vehicles: A Technology Overview
Tu, H., Feng, H., Srdic, S., & Lukic, S. (2019) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2019.2958709 · Cited by 898
The Essence of Three-Phase PFC Rectifier Systems—Part I
Kolar, J. W., & Friedli, T. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2197867 · Cited by 788
Self-citation99% Efficient Isolated Three-Phase Matrix-Type DAB Buck–Boost PFC Rectifier
Schrittwieser, L., Leibl, M., & Kolar, J. W. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2914488 · Cited by 169
Self-citationA Three-Phase Integrated Onboard Charger for Plug-In Electric Vehicles
Shi, C., Tang, Y., & Khaligh, A. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2727398 · Cited by 159
Metadata
- Authors
- Stupar, A., Friedli, T., Minibock, J., & Kolar, J. W.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2012-04
- Volume
- 27
- Issue
- 4
- Pages
- 1732-1744
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2118644343
- Cited by
- 217
- References
- 1
- FWCI
- 16.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Towards a 99% Efficient Three-Phase Buck-Type PFC Rectifier for 400-V DC Distribution Systems. https://app.cochat.ai/papers/10.1109/tpel.2011.2166406
- The paper
- Stupar, A., Friedli, T., Minibock, J., & Kolar, J. W. (2012). Towards a 99% Efficient Three-Phase Buck-Type PFC Rectifier for 400-V DC Distribution Systems. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2011.2166406
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.