The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
An Integrated Three-Port Bidirectional DC–DC Converter for PV Application on a DC Distribution System
Abstract
In this paper, an integrated three-port bidirectional dc-dc converter for a dc distribution system is presented. One port of the low-voltage side of the proposed converter is chosen as a current source port which fits for photovoltaic (PV) panels with wide voltage variation. In addition, the interleaved structure of the current source port can provide the desired small current ripple to benefit the PV panel to achieve the maximum power point tracking (MPPT). Another port of the low-voltage side is chosen as a voltage source port interfaced with battery that has small voltage variation; therefore, the PV panel and energy storage element can be integrated by using one converter topology. The voltage port on the high-voltage side will be connected to the dc distribution bus. A high-frequency transformer of the proposed converter not only provides galvanic isolation between energy sources and high voltage dc bus, but also helps to remove the leakage current resulted from PV panels. The MPPT and power flow regulations are realized by duty cycle control and phase-shift angle control, respectively. Different from the single-phase dual-half-bridge converter, the power flow between the low-voltage side and high-voltage side is only related to the phase-shift angle in a large operation area. The system operation modes under different conditions are analyzed and the zero-voltage switching can be guaranteed in the PV application even when the dc-link voltage varies. Finally, system simulation and experimental results on a 3-kW hardware prototype are presented to verify the proposed technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modeling and Control of Three-Port DC/DC Converter Interface for Satellite Applications
Qian, Z., Abdel-Rahman, O., Al-Atrash, H., & Batarseh, I. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2033926 · Cited by 399
Cited by
Zhao, B., Song, Q., Liu, W., & Sun, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2289913 · Cited by 1,886
Topologies and Control Schemes of Bidirectional DC–DC Power Converters: An Overview
Gorji, S. A., Sahebi, H. G., Ektesabi, M., & Rad, A. B. (2019) · IEEE Access · doi:10.1109/access.2019.2937239 · Cited by 439
Review of Multiport Converters for Solar and Energy Storage Integration
Bhattacharjee, A. K., Kutkut, N., & Batarseh, I. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2830788 · Cited by 423
Optimized Operation of Current-Fed Dual Active Bridge DC–DC Converter for PV Applications
Shi, Y., Li, R., Xue, Y., & Li, H. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2432093 · Cited by 298
Self-citationWang, Z., Su, X., Zeng, N., & Jiang, J. (2024) · Energies · doi:10.3390/en17102434 · Cited by 41
Self-citation
Metadata
- Authors
- Wang, Z., & Li, H.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2013-10
- Volume
- 28
- Issue
- 10
- Pages
- 4612-4624
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2021147968
- Cited by
- 230
- References
- 1
- FWCI
- 11.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Integrated Three-Port Bidirectional DC–DC Converter for PV Application on a DC Distribution System. https://app.cochat.ai/papers/10.1109/tpel.2012.2236580
- The paper
- Wang, Z., & Li, H. (2013). An Integrated Three-Port Bidirectional DC–DC Converter for PV Application on a DC Distribution System. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2012.2236580
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.