Resonance Issues and Damping Techniques for Grid-Connected Inverters With Long Transmission Cable
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
An infinite source with series inductance is usually employed as a grid emulator in grid-connected distributed generation systems. Thus, high capacitance of a transmission cable (i.e., underground cable) is too significant to be neglected. As a result, the capacitance and inductance may cause system resonance, which, in turn, challenges system stability. This paper takes offshore wind farm as an example to investigate the resonance issues caused by the submarine transmission cable of the grid-connected generation system. Based on the submarine cable model, a series of considerable resonant peaks is found in the open-loop transfer function of the grid-connected system because of the high-order LC configuration. The resonant peaks are sensitive to the system setup, which is clearly investigated. To overcome the resonances, this paper proposes a cascaded notch-filter-based active damping method to guarantee a good system stability and robustness. Furthermore, the proposed controller employs a proportional-resonant component to reduce the steady-state error of the output current. The simulation and experimental results have validated the findings of resonances and the effectiveness of the proposed controller.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
Blaabjerg, F., Teodorescu, R., Liserre, M., & Timbus, A. V. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.881997 · Cited by 5,220 · cited 1×
“a group of wind generators are connected to an onshore point of common coupling (PCC) through VSI, step-up transformers, and HVac submarine cables [6].”
BackgroundPower-Electronic Systems for the Grid Integration of Renewable Energy Sources: A Survey
Carrasco, J. M., Franquelo, L. G., Bialasiewicz, J. T., Galvan, E., PortilloGuisado, R. C., Prats, M. A. M., Leon, J. I., & Moreno-Alfonso, N. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.878356 · Cited by 4,018 · cited 1×
“A POWER electronic converter plays an important role in distributed generation and in integration of renewable energy sources into an electrical grid [1], [2].”
BackgroundA Review of Single-Phase Grid-Connected Inverters for Photovoltaic Modules
Kjaer, S. B., Pedersen, J. K., & Blaabjerg, F. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.853371 · Cited by 3,621 · cited 1×
“A POWER electronic converter plays an important role in distributed generation and in integration of renewable energy sources into an electrical grid [1], [2].”
BackgroundDesign and Control of an LCL-Filter-Based Three-Phase Active Rectifier
Liserre, M., Blaabjerg, F., & Hansen, S. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.853373 · Cited by 2,402 · cited 1×
“The popular passive damping is to insert a damping resistor in the capacitor shunt branch of the LCL filter [18], [19] or split the capacitor of the LCL filter into two parts [20].”
BackgroundVSC-Based HVDC Power Transmission Systems: An Overview
Flourentzou, N., Agelidis, V. G., & Demetriades, G. D. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2008441 · Cited by 2,216 · cited 1×
“wind turbine as an example, it often adapts back-to-back voltage source inverter (VSI) for grid connection via either highvoltage ac (HVac) or HVdc transmission cable [3], [4].”
BackgroundProportional-resonant controllers and filters for grid-connected voltage-source converters
Teodorescu, R., Blaabjerg, F., Liserre, M., & Loh, P. C. (2006) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:20060008 · Cited by 1,646
The Design of CMOS Radio-Frequency Integrated Circuits
(2004) · Microelectronics International · doi:10.1108/mi.2004.21821bae.001 · Cited by 1,456
Liserre, M., Teodorescu, R., & Blaabjerg, F. (2006) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2005.861185 · Cited by 1,101
Grid current regulation of a three-phase voltage source inverter with an LCL input filter
Twining, E., & Holmes, D. G. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.810838 · Cited by 901
HVDC Connection of Offshore Wind Farms to the Transmission System
Bresesti, P., Kling, W. L., Hendriks, R. L., & Vailati, R. (2007) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2006.889624 · Cited by 750 · cited 3×
“In fact, HVac transmission is adopted by all existing wind farms [5].”
Background
Cited by
Modeling and Analysis of Harmonic Stability in an AC Power-Electronics-Based Power System
Wang, X., Blaabjerg, F., & Wu, W. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2306432 · Cited by 785
Shair, J., Li, H., Hu, J., & Xie, X. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2021.111111 · Cited by 433
Wu, W., Liu, Y., He, Y., Chung, H. S.-H., Liserre, M., & Blaabjerg, F. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2714143 · Cited by 397
Frequency Domain Stability Analysis of MMC-Based HVdc for Wind Farm Integration
Lyu, J., Cai, X., & Molinas, M. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2015.2498182 · Cited by 267
“In [9], the high-frequency resonance issues in offshore wind farms caused by the distributed inductance and capacitance of the long-distance high-voltage ac transmission cable were investigated, and a cascaded notch-filter-based active damping method was also proposed to eliminate the resonant peaks.”
Background
Metadata
- Authors
- Zhang, S., Jiang, S., Lu, X., Ge, B., & Peng, F. Z.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2014-01
- Volume
- 29
- Issue
- 1
- Pages
- 110-120
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2012074150
- Cited by
- 218
- References
- 24
- FWCI
- 18.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.