The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Moving Average Filter Based Phase-Locked Loops: Performance Analysis and Design Guidelines
Abstract
The phase-locked loops (PLLs) are probably the most widely used synchronization technique in grid-connected applications. The main challenge that is associated with the PLLs is how to precisely and fast estimate the phase and frequency, when the grid voltage is unbalanced and/or distorted. To overcome this challenge, incorporating moving average filter(s) (MAF) into the PLL structure has been proposed in some recent literature. An MAF is a linear-phase finite-impulse-response filter, which can act as an ideal low-pass filter, if certain conditions hold. The main aim of this paper is to present the control design guidelines for a typical MAF-based PLL. The paper starts with the general description of MAFs. The main challenge associated with using the MAFs is then explained, and its possible solutions are discussed. The paper then proceeds with a brief overview of the different MAF-based PLLs. In each case, the PLL block diagram description is shown, the advantages and limitations are briefly discussed, and the tuning approach (if available) is evaluated. The paper then presents two systematic methods to design the control parameters of a typical MAF-based PLL: one for the case of using a proportional-integral (PI) type loop filter (LF) in the PLL, and the other for the case of using a proportional-integral-derivative (PID) type LF. Finally, the paper compares the performance of a well-tuned MAF-based PLL when using the PI-type LF with the results of using the PID-type LF, which provides useful insights into their capabilities and limitations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Leonhard, W. (1996) · Springer eBooks · doi:10.1007/978-3-642-97646-9 · Cited by 2,488
Operation of a phase locked loop system under distorted utility conditions
Kaura, V., & Blasko, V. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.567077 · Cited by 997
Operation of a phase locked loop system under distorted utility conditions
Kaura, V., & Blasko, V. (2002) · Proceedings of Applied Power Electronics Conference. APEC '96 · doi:10.1109/apec.1996.500517 · Cited by 903
Karimi-Ghartemani, M., & Iravani, M. R. (2004) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2004.831280 · Cited by 575
Guo, X., Wu, W., & Chen, Z. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2041738 · Cited by 475
Comparison of Three Single-Phase PLL Algorithms for UPS Applications
Santos Filho, R. M., Seixas, P. F., Cortizo, P. C., Torres, L. A. B., & Souza, A. F. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.924205 · Cited by 469
Dynamics Assessment of Advanced Single-Phase PLL Structures
Golestan, S., Monfared, M., Freijedo, F. D., & Guerrero, J. M. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2193863 · Cited by 371
Self-citationGonzalez-Espin, F., Figueres, E., & Garcerá, G. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2166236 · Cited by 295
Grid Synchronization PLL Based on Cascaded Delayed Signal Cancellation
Wang, Y. F., & Li, Y. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2099669 · Cited by 294
Synchronisation methods for grid-connected voltage source converters
Svensson, J. (2001) · IEE Proceedings - Generation, Transmission and Distribution · doi:10.1049/ip-gtd:20010101 · Cited by 284
Cited by
Fast and Robust Phase Estimation Algorithm for Heavily Distorted Grid Conditions
Zheng, L., Geng, H., & Yang, G. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2585078 · Cited by 83
Saber, C., Labrousse, D., Revol, B., & Gascher, A. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2500958 · Cited by 73
Metadata
- Authors
- Golestan, S., Ramezani, M., Guerrero, J. M., Freijedo, F. D., & Monfared, M.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2014-06
- Volume
- 29
- Issue
- 6
- Pages
- 2750-2763
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2026105850
- Cited by
- 564
- References
- 21
- FWCI
- 38.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Moving Average Filter Based Phase-Locked Loops: Performance Analysis and Design Guidelines. https://app.cochat.ai/papers/10.1109/tpel.2013.2273461
- The paper
- Golestan, S., Ramezani, M., Guerrero, J. M., Freijedo, F. D., & Monfared, M. (2014). Moving Average Filter Based Phase-Locked Loops: Performance Analysis and Design Guidelines. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2013.2273461
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.