A Bidirectional-Switch-Based Wide-Input Range High-Efficiency Isolated Resonant Converter for Photovoltaic Applications
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Modular photovoltaic (PV) power conditioning systems (PCSs) require a high-efficiency dc-dc converter stage capable of regulation over a wide input voltage range for maximum power point tracking. In order to mitigate ground leakage currents and to be able to use a high-efficiency, nonisolated grid-tied inverter, it is also desirable for this microconverter to provide galvanic isolation between the PV module and the inverter. This paper presents a novel, isolated topology that is able to meet the high efficiency over a wide input voltage range requirement. This topology yields high efficiency through low circulating currents, zero-voltage switching (ZVS) and low-current switching of the primary side devices, ZCS of the output diodes, and direct power transfer to the load for the majority of switching cycle. This topology is also able to provide voltage regulation through basic fixed-frequency pulsewidth modulated (PWM) control. These features are able to be achieved with the simple addition of a secondary-side bidirectional ac switch to the isolated series resonant converter. Detailed analysis of the operation of this converter is discussed along with a detailed design procedure. Experimental results of a 300-W prototype are given. The prototype reached a peak power stage efficiency of 98.3% and a California Energy Commission (CEC) weighted power stage efficiency of 98.0% at the nominal input voltage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fundamentals of Power Electronics
Erickson, R. W., & Maksimović, D. (2001) · Springer eBooks · doi:10.1007/b100747 · Cited by 6,112
Comparison of Photovoltaic Array Maximum Power Point Tracking Techniques
Esram, T., & Chapman, P. L. (2007) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2006.874230 · Cited by 5,425 · cited 1×
“In order to verify the functionality of the proposed converter for PV applications, a very simple perturb and observe (P&O) MPPT algorithm was implemented [8]–[10].”
MethodA Review of Single-Phase Grid-Connected Inverters for Photovoltaic Modules
Kjaer, S. B., Pedersen, J. K., & Blaabjerg, F. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.853371 · Cited by 3,621
Power electronics as efficient interface in dispersed power generation systems
Blaabjerg, F., Chen, Z., & Kjaer, S. B. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833453 · Cited by 2,588
Evaluation of the Main MPPT Techniques for Photovoltaic Applications
de Brito, M. A. G., Galotto, L., Sampaio, L. P., Melo, G. D. A. E., & Canesin, C. A. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2198036 · Cited by 1,678 · cited 1×
“In order to verify the functionality of the proposed converter for PV applications, a very simple perturb and observe (P&O) MPPT algorithm was implemented [8]–[10].”
MethodLi, Q., & Wolfs, P. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.920883 · Cited by 1,153 · cited 1×
“These modular configurations are very attractive because of more efficient energy harvesting and simple scalability [7].”
BackgroundLLC resonant converter for front end DC/DC conversion
Yang, B., Lee, F. C., Zhang, A. J., & Huang, G. (2003) · APEC. Seventeenth Annual IEEE Applied Power Electronics Conference and Exposition (Cat. No.02CH37335) · doi:10.1109/apec.2002.989382 · Cited by 1,029
Implementation of a DSP-controlled photovoltaic system with peak power tracking
Hua, C., Lin, J., & Shen, C. (1998) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.661310 · Cited by 706
Review and Comparison of Step-Up Transformerless Topologies for Photovoltaic AC-Module Application
Meneses, D., Blaabjerg, F., García, Ó., & Cobos, J. A. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2227820 · Cited by 533 · cited 1×
“therefore are more common in todays’ PV installations [6].”
BackgroundAn LLC Resonant DC–DC Converter for Wide Output Voltage Range Battery Charging Applications
Musavi, F., Craciun, M., Gautam, D. S., Eberle, W., & Dunford, W. G. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2241792 · Cited by 498 · cited 1×
“There has been some research done on optimizing the LLC converter for wide range applications [23]–[26], but”
Background
Cited by
The 2018 GaN power electronics roadmap
Amano, H., Baines, Y., Beam, E., Borga, M., Bouchet, T., Chalker, P. R., Charles, M., Chen, K. J., Chowdhury, N., Chu, R., et al. (2018) · Journal of Physics D: Applied Physics · doi:10.1088/1361-6463/aaaf9d · Cited by 1,313
Distributed Optimization for Multiagent Systems: An Edge-Based Fixed-Time Consensus Approach
Ning, B., Han, Q.-L., & Zuo, Z. (2019) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2017.2766762 · Cited by 328
Sun, X., Shen, Y., Zhu, Y., & Guo, X. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2358453 · Cited by 215
“LLC resonant converter is not suitable for wide input voltage range applications [17]–[18], [27].”
BackgroundWang, X., Jiang, C., Lei, B., Teng, H., Bai, H. K., & Kirtley, J. L. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2016.2575921 · Cited by 107
Highly Efficient and Reliable SiC-Based DC–DC Converter for Smart Transformer
Costa, L. F., Buticchi, G., & Liserre, M. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2696481 · Cited by 67
Metadata
- Authors
- LaBella, T., Yu, W., Lai, J.-S., Senesky, M., & Anderson, D.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2014-07
- Volume
- 29
- Issue
- 7
- Pages
- 3473-3484
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2048111226
- Cited by
- 188
- References
- 18
- FWCI
- 9.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.