The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Nonlinear-Disturbance-Observer-Based DC-Bus Voltage Control for a Hybrid AC/DC Microgrid
Abstract
DC-bus voltage control is an important task in the operation of a dc or a hybrid ac/dc microgrid system. To improve the dc-bus voltage control dynamics, traditional approaches attempt to measure and feedforward the load or source power in the dc-bus control scheme. However, in a microgrid system with distributed dc sources and loads, the traditional feedforward-based methods need remote measurement with communications. In this paper, a nonlinear disturbance observer (NDO) based dc-bus voltage control is proposed, which does not need the remote measurement and enables the important “plug-and-play” feature. Based on this observer, a novel dc-bus voltage control scheme is developed to suppress the transient fluctuations of dc-bus voltage and improve the power quality in such a microgrid system. Details on the design of the observer, the dc-bus controller and the pulsewidth-modulation (PWM) dead-time compensation are provided in this paper. The effects of possible dc-bus capacitance variation are also considered. The performance of the proposed control strategy has been successfully verified in a 30 kVA hybrid microgrid including ac/dc buses, battery energy storage system, and photovoltaic (PV) power generation system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075
Cited by
DC Microgrids—Part II: A Review of Power Architectures, Applications, and Standardization Issues
Dragicevic, T., Lu, X., Vasquez, J. C., & Guerrero, J. M. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2464277 · Cited by 1,451
Disturbance Observer-Based Robust Control and Its Applications: 35th Anniversary Overview
Sariyildiz, E., Oboe, R., & Ohnishi, K. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2903752 · Cited by 546
Hybrid ac/dc microgrids—Part I: Review and classification of topologies
Unamuno, E., & Barrena, J. A. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.07.194 · Cited by 399
Hybrid AC–DC Microgrid: Systematic Evaluation of Control Strategies
Gupta, A., Doolla, S., & Chatterjee, K. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2727344 · Cited by 355
Metadata
- Authors
- Wang, C., Li, X., Guo, L., & Li, Y. W.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2014-11
- Volume
- 29
- Issue
- 11
- Pages
- 6162-6177
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2315072154
- Cited by
- 215
- References
- 1
- FWCI
- 20.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Nonlinear-Disturbance-Observer-Based DC-Bus Voltage Control for a Hybrid AC/DC Microgrid. https://app.cochat.ai/papers/10.1109/tpel.2013.2297376
- The paper
- Wang, C., Li, X., Guo, L., & Li, Y. W. (2014). A Nonlinear-Disturbance-Observer-Based DC-Bus Voltage Control for a Hybrid AC/DC Microgrid. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2013.2297376
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.