A Repetitive Control Scheme for Harmonic Suppression of Circulating Current in Modular Multilevel Converters
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
In a modular multilevel converter (MMC), the interaction between switching actions and fluctuating capacitor voltages of the submodules results in second- and other even-order harmonics in the circulating currents. These harmonic currents will introduce extra power loss, increase current stress of power devices, and even cause instability during transients. Traditional methods for circulating current harmonic suppression have problems such as limited harmonic rejection capability, limited application area, and complex implementation. This paper presents a plug-in repetitive control scheme to solve the problem. It combines the high dynamics of PI controller and good steady-state harmonic suppression of the repetitive controller, and minimizes the interference between the two controllers. It is suitable for multiple harmonic suppression, easy to implement, and applicable for both single-phase and three-phase MMCs. Simulation and experimental results on a single-phase MMC inverter proved the validity of the proposed control method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recent Advances and Industrial Applications of Multilevel Converters
Kouro, S., Malinowski, M., Gopakumar, K., Pou, J., Franquelo, L. G., Wu, B., Rodriguez, J., Pérez, M. A., & Leon, J. I. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2049719 · Cited by 3,872 · cited 1×
“MULTILEVEL converters have successfully made their way into industrial high-power applications [1].”
BackgroundAn innovative modular multilevel converter topology suitable for a wide power range
Lesnicar, A., & Marquardt, R. (2004) · 2003 IEEE Bologna Power Tech Conference Proceedings, · doi:10.1109/ptc.2003.1304403 · Cited by 2,908
Feedback Control of Dynamic Systems
Franklin, G. F., Powell, D. J., & Emami-Naeini, A. (1986) · Cited by 2,293
Control and Experiment of Pulsewidth-Modulated Modular Multilevel Converters
Hagiwara, M., & Akagi, H. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2014236 · Cited by 1,565 · cited 1×
“In [10], a PI controller is used to suppress the circulating current harmonics.”
MethodTu, Q., Xu, Z., & Xu, L. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2115258 · Cited by 1,387 · cited 1×
“In [11], a pair of PI controllers based on double line-frequency, negative-sequence rotating frame, are utilized to eliminate the second-order har-”
MethodClassification, Terminology, and Application of the Modular Multilevel Cascade Converter (MMCC)
Akagi, H. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2143431 · Cited by 1,172
On dynamics and voltage control of the Modular Multilevel Converter
Antonopoulos, A., Ängquist, L., & Nee, H. (2009) · European Conference on Power Electronics and Applications · Cited by 831
A New AC/AC Multilevel Converter Family
Glinka, M., & Marquardt, R. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.843973 · Cited by 772
Ilves, K., Antonopoulos, A., Norrga, S., & Nee, H.-P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2159809 · Cited by 578 · cited 2×
“of steady-state circulating current has been given in [5] and [6].”
BackgroundA Steady-State Analysis Method for a Modular Multilevel Converter
Song, Q., Liu, W., Li, X., Rao, H., Xu, S., & Li, L. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2227818 · Cited by 503 · cited 2×
“of steady-state circulating current has been given in [5] and [6].”
Background
Cited by
Dekka, A., Wu, B., Fuentes, R. L., Perez, M., & Zargari, N. R. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2742938 · Cited by 576
“To overcome these problems, a cascade structure of repetitive controller and a PI regulator is presented in [151].”
Modular Multilevel Converters for Transportation Electrification: Challenges and Opportunities
Ronanki, D., & Williamson, S. S. (2018) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2018.2792330 · Cited by 345
“in the literature [29]–[33] and the most popular ones are”
BackgroundLi, X., Song, Q., Liu, W., Xu, S., Zhu, Z., & Li, X. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2480748 · Cited by 166
“The main existing circulating current control strategies are injecting second-harmonic voltages [10], injecting multiple harmonic voltages [12], [13], [15], predictive control [11], and openloop control [21].”
BackgroundAnalysis and Injection Control of Circulating Current for Modular Multilevel Converters
Wang, J., Han, X., Ma, H., & Bai, Z. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2808901 · Cited by 109
Li, J., Konstantinou, G., Wickramasinghe, H. R., Pou, J., Wu, X., & Jin, X. (2018) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2017.2747079 · Cited by 49
“A repetitive control scheme is also introduced for suppressing the circulating current of MMC [27].”
BackgroundMethod
Metadata
- Authors
- He, L., Zhang, K., Xiong, J., & Fan, S.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2015-01
- Volume
- 30
- Issue
- 1
- Pages
- 471-481
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2335051571
- Cited by
- 238
- References
- 21
- FWCI
- 13.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.