Circulating Current Suppressing Strategy for MMC-HVDC Based on Nonideal Proportional Resonant Controllers Under Unbalanced Grid Conditions
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Modular multilevel converter (MMC) is considered as a promising topology for voltage-source converter (VSC) high-voltage, direct current (HVDC) applications. This paper presents a new control strategy for MMC-HVDC under unbalanced grid conditions. First, a new inner loop current control strategy based on nonideal proportional resonant (PR) controllers in stationary αβ frame is designed, which is more concise compared to the existing dual sequence current control scheme. Second, an analytical expression for circulating current is obtained which shows that the circulating currents will be asymmetric under unbalanced grid conditions and can be decomposed into positive-, negative-, and zero-sequence component. In order to suppress all these components, a new circulating current suppressing strategy is analyzed and designed also based on nonideal PR controllers. Application of nonideal PR controllers makes the control system well adapt to the fluctuation of grid frequency. The effectiveness of the proposed control strategy is verified through a simulation case of a 251-level MMC-HVDC transmission system using real-time digital simulator.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An innovative modular multilevel converter topology suitable for a wide power range
Lesnicar, A., & Marquardt, R. (2004) · 2003 IEEE Bologna Power Tech Conference Proceedings, · doi:10.1109/ptc.2003.1304403 · Cited by 2,908
Tu, Q., Xu, Z., & Xu, L. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2115258 · Cited by 1,387 · cited 2×
“Some voltage-balancing algorithms, by sorting the capacitors’ voltage, were proposed in [12], [19]–[21].”
BackgroundDynamic Performance of a Modular Multilevel Back-to-Back HVDC System
Saeedifard, M., & Iravani, R. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2050787 · Cited by 1,188
Modulation, Losses, and Semiconductor Requirements of Modular Multilevel Converters
Rohner, S., Bernet, S., Hiller, M., & Sommer, R. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2031187 · Cited by 934
On dynamics and voltage control of the Modular Multilevel Converter
Antonopoulos, A., Ängquist, L., & Nee, H. (2009) · European Conference on Power Electronics and Applications · Cited by 831
Marquardt, R. (2010) · The 2010 International Power Electronics Conference - ECCE ASIA - · doi:10.1109/ipec.2010.5544594 · Cited by 773
A New AC/AC Multilevel Converter Family
Glinka, M., & Marquardt, R. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.843973 · Cited by 772
Guan, M., & Xu, Z. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2192752 · Cited by 549
Predictive Control of a Modular Multilevel Converter for a Back-to-Back HVDC System
Qin, J., & Saeedifard, M. (2012) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2012.2191577 · Cited by 428
Impact of Sampling Frequency on Harmonic Distortion for Modular Multilevel Converter
Tu, Q., & Xu, Z. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2078837 · Cited by 383
Cited by
Dekka, A., Wu, B., Fuentes, R. L., Perez, M., & Zargari, N. R. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2742938 · Cited by 576
Leon, J. I., Vazquez, S., & Franquelo, L. G. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2726583 · Cited by 481
Analysis and Injection Control of Circulating Current for Modular Multilevel Converters
Wang, J., Han, X., Ma, H., & Bai, Z. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2808901 · Cited by 109
Gong, Z., Wu, X., Dai, P., & Zhu, R. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2844836 · Cited by 106
Arm Current Control Strategy for MMC-HVDC Under Unbalanced Conditions
Liang, Y., Liu, J., Zhang, T., & Yang, Q. (2017) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2016.2554620 · Cited by 81
“If negative-sequence current is eliminated during the fault period, there are double line-frequency negative- and zerosequence circulating currents [8] .”
BackgroundMethodA Postfault Strategy to Control the Modular Multilevel Converter Under Submodule Failure
Yang, Q., Qin, J., & Saeedifard, M. (2016) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2449875 · Cited by 69
Guo, C., Yang, J., & Zhao, C. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2831193 · Cited by 53
Capacitor Voltage Estimation Scheme With Reduced Number of Sensors for Modular Multilevel Converters
Abushafa, O. S. M., Gadoue, S. M., Dahidah, M. S. A., Atkinson, D. J., & Missailidis, P. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2797245 · Cited by 53
Li, B., Xu, Z., Shi, S., Xu, D., & Wang, W. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2737541 · Cited by 51
“To solve this problem, a series of paralleled proportional resonant controllers have been proposed in [5] and [6] which show good circulating current suppression performance at the selected resonant frequency and do not need to consider three-phase unbalances.”
BackgroundLi, J., Konstantinou, G., Wickramasinghe, H. R., Pou, J., Wu, X., & Jin, X. (2018) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2017.2747079 · Cited by 49
Capacitor Voltage Reduction in Modular Multilevel Converters Under Grid Voltages Unbalances
Li, J., Konstantinou, G., Wickramasinghe, H. R., Townsend, C. D., & Pou, J. (2020) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2019.2919788 · Cited by 24
Metadata
- Authors
- Li, S., Wang, X., Yao, Z., Li, T., & Peng, Z.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2015-01
- Volume
- 30
- Issue
- 1
- Pages
- 387-397
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2334364074
- Cited by
- 343
- References
- 22
- FWCI
- 16.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.