CoChat

Liquid Jet Impingement Cooling of a Silicon Carbide Power Conversion Module for Vehicle Applications

Gould, Kyle, Cai, Steve Q., Neft, Charles, Bhunia, Avijit · 2015 · IEEE Transactions on Power Electronics

The DOI matches its Crossref record; 19 of the 24 references it cites were found in a registry or an index.

Abstract

Thermal management of power electronics is an extremely challenging problem in the harsh environment of military hybrid vehicles, where the local air and liquid coolant's temperature exceed 100 °C under regular operating conditions. This paper presents the development work of a high heat flux, jet impingement-cooled heat exchanger for a 600-V/50-A silicon carbide (SiC) power module (rated at 175 °C device junction temperature), used for bidirectional power conversion between a 28-V battery and a 300-V dc bus. A total of 50 volume% mixture of water-ethylene glycol (WEG) coolant at 100 °C inlet temperature is the only available coolant. An array of WEG coolant microjets impinges on the base plate of the SiC module. The jet impingement cooling system has been optimized by experimental studies on a surrogate module, along with a high-fidelity computational model, to accurately estimate the SiC device junction temperature in relevant operating conditions. Results indicate that at the design heat load of 151 W (worst-case scenario), the SiC device junction temperature is reduced from 290 °C with commercial-off-the-shelf (COTS) cold plate cooling and 215 °C with COTS microchannel heat exchanger cooling, to 169 °C with a jet impingement-cooled heat exchanger, using the same flow rate.

Overview

Integrity signals

Registry

Crossref · 10.1109/tpel.2014.2331562

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 2

  1. rohsenow, 1998, Natural convection, Handbook of Heat Transfer, 4.12
  2. mitic, 2002, Spray cooling of IGBT electronic power modules, Proc Int Conf Thermal Challenges Next Generat Electron Syst, 147

Cited by

See all 96

Metadata

Authors
Gould, K., Cai, S. Q., Neft, C., & Bhunia, A.
Affiliations
Teledyne Technologies (United States) (US)
Venue
IEEE Transactions on Power Electronics
Published
2015-06
Volume
30
Issue
6
Pages
2975-2984
ISSN
  • 0885-8993 (ISSN-L)
  • 1941-0107
OpenAlex
W2039385801
Cited by
93
References
24
Citations by year
2026: 5 · 2025: 8 · 2024: 8 · 2023: 7 · 2022: 12 · 2021: 9 · 2020: 12 · 2019: 11 · 2018: 8 · 2017: 9 · 2016: 2 · 2015: 2
FWCI
5.04
Type
journal article
Language
en
Open access
closed
Locations
IEEE Transactions on Power Electronics (publishedVersion)
Funders
U.S. Army Tank and Automotive Research Development & Engineering Center (W56HZV-10-C-0114)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Silicon Carbide Semiconductor Technologies
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer Mechanisms
Keywords
silicon carbide power modules, power electronics thermal management, ethylene glycol-water coolant, junction temperature, bidirectional power conversion, hybrid electric vehicles, military vehicles, high heat flux cooling, heat exchanger design

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.