The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Technical Assessment of Load Commutation Switch in Hybrid HVDC Breaker
Abstract
The development of a large-scale high-voltage direct current (HVDC) power grid requires a reliable, fast, and low-loss circuit breaker. The load commutation switch (LCS) is an essential part of ABB's 1200-MW hybrid HVDC breaker concept, which builds up a low-loss conducting path for the load current. The technical requirements for the LCS are expressed in this paper by studying the operation principle of the hybrid HVDC breaker. The voltage stress over the LCS is determined based on a dc grid with 320 and 2 kA rated voltage and current. A system model of the hybrid HVDC breaker is developed in PSCAD/EMTDC to study the design criteria for snubber circuit and arrester blocks. It is observed that conventional snubber circuits are not suitable for a bidirectional LCS as the current of snubber capacitors prevent the fast interruption action. A modified snubber circuit is proposed in this paper along with two more alternatives for the LCS to overcome this problem. Moreover, the power loss model for a semiconductor device is discussed in this paper based on the 4.5-kV StakPak IGBT. The model is used to calculate the conduction power losses for different LCS topologies. Ultimately, a matrix of 3 X 3 IGBT modules is selected to provide a reliable LCS design which can handle several internal fault cases with no interruption of operation. A full-scale prototype has been constructed and tested in ABB HVDC Center, Ludvika, Sweden. The experimental test results are also included in the paper in order to verify the calculation and simulation study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
VSC-Based HVDC Power Transmission Systems: An Overview
Flourentzou, N., Agelidis, V. G., & Demetriades, G. D. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2008441 · Cited by 2,216
HVDC Circuit Breakers: A Review Identifying Future Research Needs
Franck, C. M. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2095889 · Cited by 909
Proactive Hybrid HVDC Breakers - A key Innovation for Reliable HVDC Grids
Häfner, J., & Jacobson, B. (2011) · Medical Entomology and Zoology · Cited by 556
Self-citation
Cited by
Ruffing, P., Collath, N., Brantl, C., & Schnettler, A. (2019) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2018.2883861 · Cited by 48
Metadata
- Authors
- Hassanpoor, A., Hafner, J., & Jacobson, B.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2015-10
- Volume
- 30
- Issue
- 10
- Pages
- 5393-5400
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2107869960
- Cited by
- 334
- References
- 3
- FWCI
- 10.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Technical Assessment of Load Commutation Switch in Hybrid HVDC Breaker. https://app.cochat.ai/papers/10.1109/tpel.2014.2372815
- The paper
- Hassanpoor, A., Hafner, J., & Jacobson, B. (2015). Technical Assessment of Load Commutation Switch in Hybrid HVDC Breaker. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2014.2372815
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.