Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 181

The DOI matches its Crossref record.

Evaluation of Switching Performance of SiC Devices in PWM Inverter-Fed Induction Motor Drives

Zhang, Zheyu, Wang, Fred, Tolbert, Leon M., Blalock, Benjamin J., Costinett, Daniel J. · 2015 · IEEE Transactions on Power Electronics

Abstract

Double pulse test (DPT) is a widely accepted method to evaluate the switching characteristics of semiconductor switches, including SiC devices. However, the observed switching performance of SiC devices in a PWM inverter for induction motor drives is almost always worse than the DPT characterization, with slower switching speed, more switching losses, and more serious parasitic ringing. This paper systematically investigates the factors that limit the SiC switching performance from both the motor side and inverter side, including the load characteristics of induction motor and power cable, two more phase legs for the three-phase PWM inverter in comparison with the DPT, and the parasitic capacitive coupling effect between power devices and heat sink. Based on a three-phase PWM inverter with 1200 V SiC MOSFETs, test results show that the induction motor, especially with a relatively long power cable, will significantly impact the switching performance, leading to a switching time increase by a factor of 2, switching loss increase up to 30% in comparison with that yielded from DPT, and serious parasitic ringing with 1.5 μs duration, which is more than 50 times of the corresponding switching time. In addition, the interactions among the three phase legs cannot be ignored unless the decoupling capacitors are mounted close to each phase leg to support the dc bus voltage during switching transients. Also, the coupling capacitance due to the heat sink equivalently increases the junction capacitance of power devices; however, its influence on the switching behavior in the motor drives is small considering the relatively large capacitance of the motor load.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tpel.2014.2375827

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 181

Metadata

Authors
Zhang, Z., Wang, F., Tolbert, L. M., Blalock, B. J., & Costinett, D. J.
Venue
IEEE Transactions on Power Electronics
Published
2015-10
Volume
30
Issue
10
Pages
5701-5711
ISSN
  • 0885-8993 (ISSN-L)
  • 1941-0107
OpenAlex
W2136220673
Cited by
181
References
0
FWCI
6.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of Switching Performance of SiC Devices in PWM Inverter-Fed Induction Motor Drives. https://app.cochat.ai/papers/10.1109/tpel.2014.2375827
The paper
Zhang, Z., Wang, F., Tolbert, L. M., Blalock, B. J., & Costinett, D. J. (2015). Evaluation of Switching Performance of SiC Devices in PWM Inverter-Fed Induction Motor Drives. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2014.2375827

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.