High-Frequency-Link-Based Grid-Tied PV System With Small DC-Link Capacitor and Low-Frequency Ripple-Free Maximum Power Point Tracking
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
This paper proposes a grid-tied photovoltaic (PV) system consisting of modular current-fed dual-active-bridge (CF-DAB) dc-dc converter with cascaded multilevel inverter. The proposed converter allows a small dc-link capacitor in the three-phase wye-connected PV system; therefore, the system reliability can be improved by replacing electrolytic capacitors with film capacitors. The low-frequency ripple-free maximum power point tracking (MPPT) is also realized in the proposed converter. First of all, to minimize the influence resulting from reduced capacitance, a dc-link voltage synchronizing control is developed. Then, a detailed design of power mitigation control based on CF-DAB dynamic model is presented to prevent the large low-frequency voltage variation propagating from the dc-link to PV side. Finally, a novel variable step-size MPPT algorithm is proposed to ensure not only high MPPT efficiency, but also fast maximum power extraction under rapid irradiation change. A downscaled 5-kW PV converter module with a small dc-link capacitor was built in the laboratory with the proposed control and MPPT algorithm, and experimental results are given to validate the converter performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Review of Single-Phase Grid-Connected Inverters for Photovoltaic Modules
Kjaer, S. B., Pedersen, J. K., & Blaabjerg, F. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.853371 · Cited by 3,621 · cited 1×
“As mentioned in [14], the voltage ripple should be kept below 8.”
BackgroundOptimization of Perturb and Observe Maximum Power Point Tracking Method
Femia, N., Petrone, G., Spagnuolo, G., & Vitelli, M. (2005) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2005.850975 · Cited by 3,002 · cited 3×
“However, this modification increases the computational burden and still may have MPPT failure during rapid irradiation change [24].”
BackgroundMethodA Survey on Cascaded Multilevel Inverters
Malinowski, M., Gopakumar, K., Rodriguez, J., & Pérez, M. A. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2030767 · Cited by 2,322
A Variable Step Size INC MPPT Method for PV Systems
Liu, F., Duan, S., Liu, F., Liu, B., & Kang, Y. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.920550 · Cited by 1,313 · cited 1×
“The variable step-size of INC is accurate at steady state, but the dynamic of the MPPT is not good mainly due to the degression of the iteration step size [25].”
BackgroundA Novel Improved Variable Step-Size Incremental-Resistance MPPT Method for PV Systems
Mei, Q., Shan, M., Liu, L., & Guerrero, J. M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2064275 · Cited by 637 · cited 2×
“A modified variable step-size INC MPPT with an adaptive scaling factor is utilized in [26] to improve tracking speed during the transient.”
MethodReliability Issues in Photovoltaic Power Processing Systems
Petrone, G., Spagnuolo, G., Teodorescu, R., Veerachary, M., & Vitelli, M. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.924016 · Cited by 579 · cited 1×
“Though electrolytic capacitor has high capacitance density, it has been considered as a particularly unreliable component, which is on average 30 times less reliable than nonelectrolytic capacitor under identical conditions [8], [9].”
BackgroundGlobal Warming: Energy, Environmental Pollution, and the Impact of Power Electronics
Bose, B. K. (2010) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2010.935860 · Cited by 536 · cited 1×
“PHOTOVOLTAIC (PV) energy has become one of the most popular sustainable energy sources nowadays [1].”
BackgroundA Technique for Improving P&O MPPT Performances of Double-Stage Grid-Connected Photovoltaic Systems
Femia, N., Petrone, G., Spagnuolo, G., & Vitelli, M. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2029589 · Cited by 503 · cited 1×
“If this voltage ripple propagates to the PV side, it will deteriorate the MPPT performance and decrease the MPPT efficiency [13]–[15].”
BackgroundThree-Port Triple-Half-Bridge Bidirectional Converter With Zero-Voltage Switching
Tao, H., Duarte, J. L., & Hendrix, M. A. M. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.915023 · Cited by 404
Jiang, S., Cao, D., Li, Y., & Peng, F. Z. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2183389 · Cited by 245 · cited 2×
“Several isolated current-fed dc–dc converters have been studied for various applications [16]–[22].”
BackgroundWang, Z., & Li, H. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2236580 · Cited by 230 · cited 1×
“In [21], a three-phase currentfed dual-active-bridge (CF-DAB3) converter is proposed for PV application on a dc distributed system.”
BackgroundSelf-citationLiu, L., Li, H., Xue, Y., & Liu, W. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2333004 · Cited by 212 · cited 3×
“A detailed active and reactive power compensation and optimization strategy for the inverter control has been reported in [5] and [6]; therefore, this paper only focuses on the control for dc–dc module.”
BackgroundMethodSelf-citationHarb, S., & Balog, R. S. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2222447 · Cited by 204
Sullivan, C. R., Awerbuch, J. J., & Latham, A. M. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2205162 · Cited by 174 · cited 1×
“If this voltage ripple propagates to the PV side, it will deteriorate the MPPT performance and decrease the MPPT efficiency [13]–[15].”
BackgroundFull-bridge isolated current fed converter with active clamp
Yakushev, V., Meleshin, V., & Fraidlin, S. (1999) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.1999.749736 · Cited by 157
An Integrated Boost Resonant Converter for Photovoltaic Applications
York, B., Yu, W., & Lai, J. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2207127 · Cited by 133
An improved reliability cuk based solar inverter with sliding mode control
Knight, J., Shirsavar, S. A., & Holderbaum, W. (2006) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.876786 · Cited by 111
Liu, X., Li, H., & Wang, Z. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2251004 · Cited by 109 · cited 2×
“Several isolated current-fed dc–dc converters have been studied for various applications [16]–[22].”
BackgroundSelf-citationShi, Y., Liu, L., Li, H., & Xue, Y. S. (2013) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2013.6647006 · Cited by 34 · cited 4×
“The dc-link capacitance required to buffer the energy can be calculated by (1) as derived in [23].”
BackgroundMethodSelf-citation
Cited by
Tong, A., Hang, L., Li, G., Jiang, X., & Gao, S. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2692276 · Cited by 455
Circulating Current and ZVS-on of a Dual Active Bridge DC-DC Converter: A Review
Shao, S., Chen, H., Wu, X., Zhang, J., & Sheng, K. (2019) · IEEE Access · doi:10.1109/access.2019.2911009 · Cited by 200
“[69], CF-DAB gains growing recognition in energy storage and photovoltaic (PV) applications [70], [71].”
Background
Metadata
- Authors
- Shi, Y., Li, R., Xue, Y., & Li, H.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2016-01
- Volume
- 31
- Issue
- 1
- Pages
- 328-339
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2003768412
- Cited by
- 194
- References
- 19
- FWCI
- 7.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.