The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
A Real-Time Multiple Open-Circuit Fault Diagnosis Method in Voltage-Source-Inverter Fed Vector Controlled Drives
Abstract
This paper proposed a fast, real-time and fair robustness scheme for single switch and double switches open-circuit fault diagnosis in pulse-width-modulated voltage source inverter (VSI) for vector-controlled induction motor drives based on three phase output currents, which is also easy to insert into the controlled algorithm as a subroutine without major modification. The concept of allelic points is proposed and corresponding functions are defined to describe the symmetry of the VSI physical topology under healthy and faulty conditions. The residuals between any two phase functions are applied as criterion for allelic points. Under healthy condition, three legs are symmetrical and the residuals are all closed to zero, when open-circuit fault occurs, the residuals will be larger than a predefined threshold, so it is used to detect fault occurrence. When fault occurs, the near-zero current samples per fundamental period will get large, its proportions in a period will be different when different fault classes occur. The fault can be located combined the functions and residuals based on the analysis of VSI topology. The simulations and experiments are carried out and the results show the effectiveness and the merits of the proposed method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Condition Monitoring for Device Reliability in Power Electronic Converters: A Review
Yang, S., Xiang, D., Bryant, A., Mawby, P., Ran, L., & Tavner, P. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2049377 · Cited by 1,278
A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. K. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027535 · Cited by 985
Estima, J. O., & Marques Cardoso, A. J. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2188877 · Cited by 377 · cited 1×
“The literature [32] used the residual obtained by comparing the measured stator phase current and its reference signals as the features for fault detection and isolation, it is simple to implement but it performs weakly relate to open-loop control strategies such as V/f control.”
Method
Cited by
A Data-Driven Fault Diagnosis Methodology in Three-Phase Inverters for PMSM Drive Systems
Cai, B., Zhao, Y., Liu, H., & Xie, M. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2608842 · Cited by 471
Diagnosis of Open-Switch and Current Sensor Faults in PMSM Drives Through Stator Current Analysis
Khojet El Khil, S., Jlassi, I., Marques Cardoso, A. J., Estima, J. O., & Mrabet-Bellaaj, N. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2930592 · Cited by 147
Wu, F., & Zhao, J. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2587339 · Cited by 82
“An, L.-Z. Sun, K. Zhao, and L. Sun, “Switching function modelbased fast-diagnostic method of open-switch faults in inverters without sensors,” IEEE Trans.”
BackgroundMethodSelf-citationTrabelsi, M., Semail, E., & Nguyen, N. K. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2719634 · Cited by 61
Naseri, F., Schaltz, E., Lu, K., & Farjah, E. (2020) · IET Power Electronics · doi:10.1049/iet-pel.2019.1498 · Cited by 37
Metadata
- Authors
- Wu, F., & Zhao, J.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2016-02
- Volume
- 31
- Issue
- 2
- Pages
- 1425-1437
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2015455045
- Cited by
- 181
- References
- 3
- FWCI
- 7.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.