This paper proposes a distributed coordination control method for multiple bidirectional power converters (BPCs) in a hybrid ac/dc microgrid. The researched hybrid ac/dc microgrid is composed of both ac and dc subgrids connected by multiple parallel BPCs, and only the ac subgrid contains storages for the sake of economy. The proposed control method can realize the appropriate power interaction between the two subgrids and make the two subgrids to support each other, so the hybrid microgrid can operate well in both the grid-connected and islanded modes. Concretely, there are three improvements in this proposed control methods. First, a d-q-0 three-axis control strategy instead of the conventional d-q two-axis control strategy is adopted to suppress the circulating current on the ac side generated by the multiple parallel BPCs. And then the square of the dc voltage rather than the dc voltage itself is controlled, which can make the control of the dc voltage linearized and can make the BPCs provide well voltage support for the dc subgrid. Second, the dc droop control is adopted for the dc current sharing. Also, in order to relieve the storages from generating too much reactive power if the ac load reactive power is very large in the ac subgrid, the reactive power droop control is adopted to make the BPCs share some reactive power. Third, taking the capacities and load types of the two subgrids into consideration, a coordinated control strategy based on the dc voltage versus the frequency droop is designed to realize the power interaction between the two subgrids. Furthermore, the stability analysis of the proposed control method is conducted. All the conclusions are verified by the real-time hardware-in-loop tests.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075
Cited by
Hybrid AC–DC Microgrid: Systematic Evaluation of Control Strategies
Gupta, A., Doolla, S., & Chatterjee, K. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2727344 · Cited by 355
Stability and Control Aspects of Microgrid Architectures–A Comprehensive Review
Ahmed, M., Meegahapola, L., Vahidnia, A., & Datta, M. (2020) · IEEE Access · doi:10.1109/access.2020.3014977 · Cited by 326
A novel multi-port solid state transformer enabled isolated hybrid microgrid architecture
Nair, A. C., & Fernandes, B. G. (2017) · IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2017.8216113 · Cited by 15
Metadata
- Authors
- Xia, Y., Peng, Y., Yang, P., Yu, M., & Wei, W.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2017-06
- Volume
- 32
- Issue
- 6
- Pages
- 4949-4959
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2512061132
- Cited by
- 178
- References
- 1
- FWCI
- 18.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Distributed Coordination Control for Multiple Bidirectional Power Converters in a Hybrid AC/DC Microgrid. https://app.cochat.ai/papers/10.1109/tpel.2016.2603066
- The paper
- Xia, Y., Peng, Y., Yang, P., Yu, M., & Wei, W. (2017). Distributed Coordination Control for Multiple Bidirectional Power Converters in a Hybrid AC/DC Microgrid. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2016.2603066
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.